Section 8: optional heater accessories, 1 u-tube configuration, Warning – Roberts Gorden Vantage twin Fire Unitary Infrared Heater TF-250 User Manual

Page 33

Advertising
background image

SECTION 8: O

PTIONAL

H

EATER

A

CCESSORIES

27

SECTION 8: OPTIONAL HEATER ACCESSORIES

8.1 U-Tube Configuration

The heaters are approved for optional U-Tube
configurations. This installation requires 1 or 2 U-
Tube packages depending on configuration desired.
Shown below is an example of a typical 80' (24 m) U-
Tube configuration. The U-Tube may be installed in
either a standard horizontal position or in an opposite
45° position as shown below. When designing a U-
Tube configuration, the following additional rules
must be adhered to:

• A minimum of 10' (3 m) on TF-120/160 and a min-

imum of 15' (4.5 m) on TF-200/250/300/ 350/380
is required between the burner and the U-Tube.

• The correct turbulator (

See Page 24, Step 7.5)

must be installed in the last standard section of
tube.

• The burner must never be operated in a tilted

position.

• When installed in a full 45° position, the burner

must be installed on the lower side.

• The heater must be properly supported at all loca-

tions.

See Page 29, Figure 19.

WARNING

Cut/Pinch Hazard

Wear protective gear during installation,
operation and service.

Edges are sharp.

Failure to follow these instructions can result
in injury.