Installation, Venting arrangements - vertical terminations – Regency P33R-LP2 User Manual

Page 15

Advertising
background image

Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace

15

INSTALLATION

Vent must be supported at offsets

Firestops are required at each floor level and whenever passing through a wall.

Maintain a 1-1/4" clearance to combustibles

Note: Must use optional flue adapter when using Simpson Dura-Vent pipe (Part # 510-994).

VENTING ARRANGEMENTS - VERTICAL TERMINATIONS

SIMPSON DURA-VENT DIRECT VENT GS SYSTEM

(Propane & Natural Gas)

The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations , using three 90

o

elbows

(two 45

o

elbows equal one 90

o

elbow), with Simpson Dura-Vent Direct Vent GS vent systems for Propane and Natural Gas.