Conversion Kit from Natural Gas to Propane Model #431-969

for P33R-2 using SIT 820 NOVA Gas Valve

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER

IF IN DOUBT DO NOT DO THIS CONVERSION !!

Remove the 2 screws, push Burner Assem-

bly to the left and lift out.

6) Remove the 2 Air Deflectors (2 screws per

deflector) attached to the Rear Log Sup-
port. Discard the Air Deflectors, they are
only required when burning Natural Gas.

8) Unscrew the pilot orifice with the allen key

and replace with the LP pilot orifice in the
kit and replace pilot cap.

Burner Orifice

Conversion Kit Contains:

Qty. Part #

Description

1

910-018

SIT Conversion Kit-50%
Turndown LP

1

910-037

LP Injector (Pilot Orifice)

1

904-163

Burner Orifice #54

1

908-255

Decal "Converted to Propane"

1

908-528

Red "PROPANE" label

1

908-529

5/32" Allen Key

1

908-812

Instruction Sheet

1) Shut off the gas supply.

2) Remove the louvers (and bay door if it is

installed).

3) Open the flush door and remove the door.

4) Remove the logs, embers, and brick panels

(if used).

5) Remove the 2 screws holding the Burner

Assembly to the firebox base. Push the
Burner Assembly to the left and lift out.

7) Pull off the pilot cap to expose the pilot

orifice.

Air Deflector

Air Deflector

screws

Rear Log Support

9) Remove burner orifice with a 1/2" wrench

and discard. Use another wrench to hold on
to the elbow behind the orifice.

10) Reinstall new burner orifice LP stamped

#54 and tighten.

11) Remove and discard the 3 pressure regu-

lator mounting screws (A), pressure reg-
ulator tower (B) and diaphragm (C).

12) Insure that the rubber gasket (D) is properly

positioned and install the new HI/LO pres-
sure regulator assembly to the valve using
the new screws (E) supplied with the kit.
Tighten screws securely.

13) Reverse steps 5) to 2).

14) Attach clear label "This unit has been

converted to Propane" near or on the serial
# decal. Attach white label "This valve has
been converted from NG to LPG using SIT
conversion Kit Code 0.907.202" onto the
valve.

15) Replace yellow "Natural Gas" label with

red "Propane" label

16) Check for gas leaks.

17) Check inlet and outlet pressures.

18) Check operation of flame control.

19) Check for proper flame appearance and

glow on logs.