INSTALLATION
MANTEL CLEARANCES
Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing
are shown in the diagram below.
Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible
board.
Note: Ensure the paint that is used
on the mantel and the facing is
"heat resistant" or the paint may
discolour.
MANTEL LEG CLEARANCES
Combustible mantel leg clearances as per diagram:
4"
Allowable mantel
leg projection
9” (229mm)
11” (279mm)
14-3/4” (375mm)
Side wall
L676S UNIT
1.5"
MANTEL LEG