1) Finishing material such as tile, river rock, etc. must not protrude

beyond the front facing fl anges on all 4 sides of the fi rebox opening.

2) If material such as brick, stone, etc. extends past the faceplate depth,

when fi nishing around the faceplate, the minimum opening dimension
noted below (Diagram 3) must be adhered to - to ensure the faceplate
can be removed.

36 -1/4”

34

-9/16

NON-COMBUSTIBLE REQUIREMENTS

47-5/8"

(1209mm)

6-7/16"

(163mm)

3"

(76mm)

32-1/16”

(814mm)

15-9/16"

(392mm)

29-1/16”

(738mm)

31-5/8"

(803mm)

44-1/2"

(1130mm)

Non-combustible

Material

Non-combustible Material

Non-combustible

Material

Non-combustible

Material

Metal

Stud

Finished Floor

Diagram 1

Diagram 2

Diagram 3

Diagram 4

Important:

A 3/4" gap must be maintained all around the outer edge of

the faceplate and the edge of any fi nishing material thicker than
1-1/4" (see diagram 4).


This gap is required to facilitate the installation of the faceplate and

to ensure the removal of the faceplate for service access.

Note:

All non-combustible facing material should butt up cleanly to

the fl anges around the fi rebox opening.


Rough edges may be visible, from an angle, through the 1/2" gap

behind the faceplate.


To obtain a clean edge, facing material edges may be fi nished

with a J-style trim or metal cornerbead (both materials available
at your local building or hardware outlet) see diagram 2.

Important: Materials used must be NON-COMBUSTIBLE