Regency® L676S Direct Vent Gas Fireplace

41

MAINTENANCE

MAINTENANCE

12) Unplug the green (TH) and white (TP/TH)

wires from the valve.

13) Disconnect the 2 DC Spark generator wires

from the DC spark box located in front of
the valve.

14) Disconnect the spark electrode wire from

the DC spark box.

Disconnect 2 wires

Disconnect 2 generator wires

DC Spark Box Electrode Wire

Valve Tray Out

Location of Screws.

15) Remove the 16 screws that hold the valve

tray to the fi rebox and slightly pull out the
valve tray.

17) Replace the valve tray and reverse steps

to re-install.

18) Turn on the gas supply and check for gas

leaks.

19) Re-install the inner panels.

20) Re-install the burner.

21) Re-install the pilot shield.

22) Re-install the glass door.

23) Re-install the faceplate.

24) Check the inlet and outlet pressures.

25) Check operation of fl ame control.

26) Check for proper fl ame appearance.

11) Disconnect the inlet gas line from the

valve.

16) Completely pull out the valve tray.

Advertising