Safety label, Inst alla tion, Copy of safety decal – Regency Sunrise Gas Fireplace L676S-NG1 User Manual
Page 4

INST
ALLA
TION
Regency® L676S Direct Vent Gas Fireplace
4
4
SAFETY LABEL
This is a copy of the label that accompanies
each L676S-NG1 and L676S-LP1 Direct Vent
Gas Fireplace. We have printed a copy of the
contents here for your review.
NOTE: Regency
®
units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.
COPY
OF SAFETY
DECAL
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ETIQUETTE
Listed: VENTED GAS FIREPLACE HEATER
Tested to: ANSI Z21.88a-2007/
CAN/CGA-2.17-M91
Certified for / Certifiée pour: CANADA AND U.S.A.
WN # 16074
CSA 2.33a-2007,
Serial No. / No de serie
342
`
NATURAL GAS FIREPLACE: MODEL L676S-NG1
Factory Equipped For Altitude 0-4500ft. (0-1372m)
Min. Supply Pressure
5“
WC
(1.25 kpa)
Low Setting Man. Pressure
1.6"
WC
(0.39 kpa)
Max. Manifold Pressure
3.5"
WC
(0.87 kpa)
Orifice Size
#37
DMS
Minimum Input
19,500
Btu/h
(5.71
)
Maximum Input
29,000
Btu/h
(8.49 kW)
kW
342
Model/Modele:
L676S-NG1
Model/Modele:
L676S-LP1
918-760
PROPANE GAS FIREPLACE: MODEL L676S-LP1
Factory Equipped For Altitude 0-4500ft. (0-1372m)
Min. Supply Pressure
12"
WC
(2.98 kpa)
Low Setting Man. Pressure
6.4"
WC
(1.59 kpa)
Max. Manifold Pressure
10"
WC
(2.49 kpa)
Orifice Size
#53
DMS
Minimum Input
21,000
Btu/h (6.15 kW)
Maximum Input
26,000
Btu/h (7.61 kW)
FPI Fireplace Products International Ltd., Delta BC, CANADA
MADE IN CANADA / FABRIQUE AU CANADA
Minimum Clearances to Combustibles from Fireplace Opening
Side Walls
*A
14-3/4" (375mm)
Ceiling
B
52"
(813mm)
Min. Mantel Height
C
16-1/2" (419mm)
Max. Mantel Depth
**D
13”
(330mm)
Alcove Width
E
84"
(2134mm)
Alcove Depth
F
36"
(914mm)
Finished Floor
G
3”
(76mm)
VENTED GAS FIREPLACE HEATER
This appliance must be installed in accordance with the manufacturer’s installation
instructions and with local codes, if any; if none, follow the current ANSI Z223.1 in
the USA or the current CAN 1-B149 in Canada.
This vented gas fireplace heater is not for use with air filters.
For Manufactured Home Installation: This Direct Vent System Appliance must be
installed in accordance with the manufacturer's installation instructions and
Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the
current Standard for Fire Safety Criteria for Manufactured Home Installation, Sites, and
Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in
Canada.
This appliance is only for use with the type of gas indicated on the rating plate and may
be installed in an aftermarket, permanently located, manufactured (mobile) home
where not prohibited by local codes. See owner's manual for details. This appliance is
not convertible for use with other gases, unless a certified kit is used (Kit #526-969).
Certified for use with Heat Wave (Kit #946-556).
For use with glass doors certified with the appliance only.
Electrical Supply: 6.0 VDC
NOT FOR USE WITH SOLID FUEL
D
E
F
A
B
C
Refer to Manual for complete Clearance Details
* Alcove side wall must have a min. of 14-3/4” (375mm) clearance on one side.
** Mantel depth taken at 26-1/2” (673mm) from front facing.
G