Regency® L676S Direct Vent Gas Fireplace

4

4

SAFETY LABEL

This is a copy of the label that accompanies
each L676S-NG1 and L676S-LP1 Direct Vent
Gas Fireplace. We have printed a copy of the
contents here for your review.

NOTE: Regency

®

units are constantly being

improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.

COPY

OF SAFETY

DECAL

For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.

For the State of Massachusetts, fl exible
connectors shall not exceed 36 inches in
length.

For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.

The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ETIQUETTE

Listed: VENTED GAS FIREPLACE HEATER
Tested to: ANSI Z21.88a-2007/
CAN/CGA-2.17-M91
Certified for / Certifiée pour: CANADA AND U.S.A.
WN # 16074

CSA 2.33a-2007,

Serial No. / No de serie

342

`

NATURAL GAS FIREPLACE: MODEL L676S-NG1

Factory Equipped For Altitude 0-4500ft. (0-1372m)

Min. Supply Pressure

5“

WC

(1.25 kpa)

Low Setting Man. Pressure

1.6"

WC

(0.39 kpa)

Max. Manifold Pressure

3.5"

WC

(0.87 kpa)

Orifice Size

#37

DMS

Minimum Input

19,500

Btu/h

(5.71

)

Maximum Input

29,000

Btu/h

(8.49 kW)

kW

342

Model/Modele:

L676S-NG1

Model/Modele:

L676S-LP1

918-760

PROPANE GAS FIREPLACE: MODEL L676S-LP1

Factory Equipped For Altitude 0-4500ft. (0-1372m)

Min. Supply Pressure

12"

WC

(2.98 kpa)

Low Setting Man. Pressure

6.4"

WC

(1.59 kpa)

Max. Manifold Pressure

10"

WC

(2.49 kpa)

Orifice Size

#53

DMS

Minimum Input

21,000

Btu/h (6.15 kW)

Maximum Input

26,000

Btu/h (7.61 kW)

FPI Fireplace Products International Ltd., Delta BC, CANADA

MADE IN CANADA / FABRIQUE AU CANADA

Minimum Clearances to Combustibles from Fireplace Opening

Side Walls

*A

14-3/4" (375mm)

Ceiling

B

52"

(813mm)

Min. Mantel Height

C

16-1/2" (419mm)

Max. Mantel Depth

**D

13”

(330mm)

Alcove Width

E

84"

(2134mm)

Alcove Depth

F

36"

(914mm)

Finished Floor

G

3”

(76mm)

VENTED GAS FIREPLACE HEATER

This appliance must be installed in accordance with the manufacturer’s installation
instructions and with local codes, if any; if none, follow the current ANSI Z223.1 in

the USA or the current CAN 1-B149 in Canada.

This vented gas fireplace heater is not for use with air filters.

For Manufactured Home Installation: This Direct Vent System Appliance must be
installed in accordance with the manufacturer's installation instructions and
Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the
current Standard for Fire Safety Criteria for Manufactured Home Installation, Sites, and
Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in
Canada.
This appliance is only for use with the type of gas indicated on the rating plate and may
be installed in an aftermarket, permanently located, manufactured (mobile) home
where not prohibited by local codes. See owner's manual for details. This appliance is
not convertible for use with other gases, unless a certified kit is used (Kit #526-969).
Certified for use with Heat Wave (Kit #946-556).
For use with glass doors certified with the appliance only.

Electrical Supply: 6.0 VDC

NOT FOR USE WITH SOLID FUEL

D

E

F

A

B

C

Refer to Manual for complete Clearance Details

* Alcove side wall must have a min. of 14-3/4” (375mm) clearance on one side.

** Mantel depth taken at 26-1/2” (673mm) from front facing.