www.rolandus.com

389

7.

Press the F button for the DIF-AT’s R-BUS jack to
display the DIF-AT’s settings.

8.

Set INPUT SELECT to TDIF.

9.

Press UTILITY.

10. Press PAGE until “Proj” appears above F3.
11. Press F3 (Proj)—the PROJECT PARAMETER screen

appears.

12. Set MASTER CLOCK to the R-BUS jack to which the

DIF-AT is connected.

13. Press UTILITY.
14. Press F5 (MIDI) to display the MIDI PARAMETER screen.
15. Set MMC MODE to MASTER.
16. Press UTILITY.
17. Press F6 (SYNC)—the SYNC PARAMETER screen appears.
18. Set SYNC MODE to INT.

ADA-7000 Settings

INPUT SENS 1-8

Each INPUT SENS parameter sets the input sensitivity of the corresponding ADA-7000
input jack—changing a parameter’s value is the same thing as turning the
corresponding input sensitivity knob on the front panel of the ADA-7000.

FRONT PANEL CONTROL

You can disable front-panel control of the ADA-7000 so that it can be set only from the
the VS-2480. To do this turn FRONT PANEL CONTROL off. If you want to retain control
of the ADA-7000 in both places, leave FRONT PANEL CONTROL on.

PHANTOM +48V 1-8

Turn on an input jack’s PHANTOM +48V 1-8 when you need to supply phantom power
to a condenser mic connected to the input.

When front-panel control of the ADA-7000 is turned on, the values reflect by the
position of its knobs may not agree with its actual current values, as shown on its
R-BUS REMOTE CONTROL screen.

Turn a jack’s phantom power on only when the device—typically a condenser mic—
connected to the jack requires phantom power. Activating phantom power when other
devices are connected to the jack may result in damage to the connected device.