DIGITAL OUT TYPE

This parameter selects the type of digital audio signals to be output from the
AE-7000. You can select:

•

TYPE1

—to produce digital audio that conforms to AES/EBU standards for use by

professional broadcast and recording studios. Use this setting if you wish to send
digital audio from the VS-2480 to a ProTools™ system.

•

TYPE2

—to produce S/P DIF digital audio for devices such as DAT and MiniDisc

recorders.

COPY PROTECT

When COPY PROTECT is on, SCMS copy-protection is embedded in S/P DIF digital
audio transmitted from the AE-7000—to transmit this type of audio, TYPE2 must be
selected as the DIGITAL OUT TYPE (see above). This copy-protection prevents the
creation of further copies of the digital audio. To disable copy-protection, turn COPY
PROTECT off.

VSR-880 Settings

CH STATUS 1-8

You can set the status of each track on an R-BUS-connected VSR-880. You can choose:

•

SRC

—to listen to the track’s source signal.

•

PLY

—to set the track so that it plays back any audio recorded on the track.

•

REC

—to arm the track for recording.

•

MUT

—to turn the track off.

If the AE-7000’s
CLOCK SOURCE is:

This means that
the AE-7000:

Set the VS-2480’s
MASTER CLOCK to:

R-BUS

derives master clock from the VS-2480.

a clock source other

than the AE-7000’s
R-BUS jack.

WORD CLOCK

derives its clocking from the word clock
device connected to its rear-panel
WORD CLOCK jack.

the AE-7000’s
R-BUS jack.

INPUT A

uses the master clock received by its
INPUT A jack.

the AE-7000’s
R-BUS jack.

VS2480OMUS.book 392 ページ 2006年2月7日 火曜日 午後4時16分