20

9

OPERATIONS

OSP series

portable infrared thermometers are factory calibrated before shipment.

During the start-up the operator should only select and load, if required, the pertinent application parameter as described
in the following paragraphs.
Before entering the procedure to operate the instrument it is useful the understanding of the messages that can be
present in the display.
The following figure shows the overall layout of the display and an explanation of each symbol or message :

e

+ -

Auto

K

Log Rcl Set

°F

°C

Lock Comp HAL

LAL

1

2

3

4

7

5

6

8

9

10

11

15

13

14

12

1 -

Indicates logging mode operative

2 -

Enables recall of memory stored data

3 -

Indicates the setting mode enabled during configuration and logging mode set up

4 -

Low battery indication

5 -

Temperature in degree Fahrenheit

6 -

Temperature in degree Celsius

7 -

Temperature in Kelvin

8 -

Actual measured temperature value

9 -

Indicates Low Alarm

10 -

Indicates High Alarm

11 -

Auxiliary measurement data or setting (AVG, LAL, HAL, MIN, MAX, DIF) or thermocouple input indication

12 -

Operative emissivity value

13 -

Ambient temperature compensation

14 -

Continuous measurement mode

15 -

Automatic acquisition in logging mode

The contact closure of the keys is acknowledged as a coded signal by the microprocessor that recognizes the operator’s
instructions.
<Trigger>

Keep pressed for operation. Press twice, in sequence, to hold the instrument -ON-

<

> <

>

Value setting or data selection during Configuration or Set-up procedures

<*>

Laser sighting on/off or data acquisition mode set-up

<MEM>

Data acquisition operation and logging manual step

<SEL>

Selects the operative mode

<ENTER>

Memory load key

9.1

Quick Start

To use the OSP infrared thermometer right away follow this simple steps :
Point the instrument at the object you want to measure and pull the trigger (the actual temperature value, the pre-
programmed emissivity value and the auxiliary indication will be displayed); a “LOCK” symbol will appear on display.
Set emissivity value using the <▲> and <▼> keys. Refer to appendix A to define emissivity and for emissivity tables.
Press and release the trigger to switch the unit off.

9.2

How to Operate the instrument

To switch the instrument “On” keep the trigger pressed; when the trigger is released the instrument will be switched “Off”.
When continuous operations are required press twice, in sequence, the trigger to lock the operative mode.
The first display indication will show the type of instrument and the temperature technical unit enabled.