Measuring Flatness

Measuring Flatness

This is an example of how to measure the height at 9 locations on a workpiece, and
calculate the difference (max. value - min. value) between each measured point. [MAX-
MIN] is used as the operation mode.

For details on how to connect and install the Sensor Heads and Sensor Controllers, refer to the “ZS-L
User’s Manual”.

FUN Mode-[SENSING]-[SEL CH]

1.

Assign the CH No. of the controller to inputs
A to I to be used for the expression.

INPUT A : 1CH
INPUT B : 2CH
INPUT C: 3CH
INPUT D: 4CH
INPUT E : 5CH
INPUT F : 6CH
INPUT G: 7CH
INPUT H: 8CH
INPUT I : 9CH

Input A

Input B

Input C

Input I

CH0 CH1 CH2

CH9

CH3

Input A Input B Input C

Input I

The operation and/or measurement results are output
as judgement output or linear output.