8

detaIlS regardIng the effect of aIr temperature on altItude meaSurement are ShoWn on page 51 Of

thIS guIde.
If the AltItude Is not known, the user cAn set the seA leVel Pressure In the BArometer mode (refer to

page 40, Setting the Sea level pressure).
SettIng the Sea level preSSure WIll adJuSt the altImeter to the current altItude WIthIn approXImately

ten meterS or 30 ft. a 1-mbar change reSultS approXImately an 8-meter (or 26 ft) change In altItude, and a

0,05 inhg change reSultS a 45 ft. change In altItude.
INfOrmaTION ON The CUrreNT Sea level preSSUre CaN be ObTaINed ThrOUgh NeWSpaperS, lOCal NeWS aNd

radIo Weather reportS, the local aIrport facIlIty or through the Internet under local Weather.

4.1 seTTIng THe alTIMeTeR

In setting the Altimeter, there are three processes that can be performed: the Reference Altitude (known altitude at the current location);

Altitude Alarm (signals the user when a certain altitude, programmed, is reached); and Logbook Recording Interval (allows the user to

view the altitude, average rate of vertical movement and heart rate within a chosen interval of time).
. press the [select] button and hold in for  seconds. located in field  is the text “re” (indicating reference altitude), located in

Field 2, the current altitude will begin to flash (Fig. 22).

. press the [+] button to scroll the altitude upward or press the [-] button to scroll the altitude downwards.
3. at the desired reference altitude, either press the [mode] button to accept the changes and return to the main mode or press

the [Select] button to move to the next setting. Located in Field 1, the “ON” or “OFF” will begin to flash (Fig. 23).

4. press either the [+] or the [-] button to toggle between the “on” and “off” for the altitude alarm.
5. at the desired setting, press the [select] button to move to the next setting. located in the center of field , the alarm altitude

will begin to flash.

6. press the [+] button to scroll the altitude upward or press the [-] button to scroll the altitude downwards.
7. at the desired altitude, either press the [mode] button to accept the changes and return to the main mode or press the [select]

button to move to the next setting. Located in Field 1, the text INT and located in Field 2 the time interval will begin to flash (Fig.

4).

8. PRESS either the [+] or the [-] button to scroll through the intervals. There are four time intervals: 20 seconds, 1 minute, 10 minute

or 60 minutes.