3.3.2.3 Start Fill-mode

3.3.2.3.1 Fill-mode starts automatically upon card reset
When this option is activated (checked), the card starts
automatically the Fill-mode upon reset. Otherwise (the option is
unchecked), the cards ‘awakes’ in the upper level, referred to in this
document as the ‘general mode’.

Notes
1. In order to switch the card from Fill mode to General mode, use

the ‘x’ command (small ‘x’).

2. In order to switch the card from General mode to Fill mode,

use the ‘F’ command.

3. About the ‘x’, ‘F’ and other commands in Fill mode,

refer to section E.6.