H.2 The Auto-Tare function

This function supplies a way to define the meaning of the setpoint

parameter:
* When the ‘AutoTare’ option is not activated, the setpoint
defines the requested final gross weight.

That is, if the setpoint is 100 kg and the starting gross weight

is 90 kg, the filling amount will be 10 kg.

* When the ‘AutoTare’ option is activated, the setpoint
defines the requested filling amount.

That is, if the setpoint is 100 kg, the filling amount will also

be 100 kg, regardless of the starting gross weight.

However, the filling operation will take place only if the starting

gross weight is within a user pre-defined range; otherwise, the

filling operation will be rejected and an error will be indicated.

The activation of the ‘Auto-Tare’ option as well as its parameters are

described in section E.4.1.2.