2 parameters – Omega Speaker Systems High Speed Load Cell Interface Card LCIC-WIM-BEN User Manual

Page 35

Advertising
background image

34

4.2 Parameters

Parameter

number

Parameter Description

Data

Type

1

Load Cell mV/V (1, 2 or 3. 0 = unknown).

Float

2

Units: 0=g, 1=kg, 2=ton, 3=oz, 4=lb.

Float

3

Full Load Cell(s) Capacity

Float

4

Maximum Applied Capacity

Float

5

Resolution Index (0-17)

Resolution Index is actually the index to an array of 18

defined values(0-17) like that:

0.0001, 0.0002, 0.0005,

0.001, 0.002, 0.005,

0.01, 0.02, 0.05,

0.1, 0.2, 0.5,

1, 2, 5,

10, 20, 50.

E.g., if Resolution Index=8, then system resolution =

0.05.

Float

8

Calibration Date formatted as "MMDDYY".

So, 10107 <= Calibration Date <= 123199.

Float

11

Calibration Time formatted as "HHMM".

So, 0 <= Calibration Time <=2359

Float

20

Auto transmit interval (3-52734, integer).

How many internal adc updates (52734 Hz) there are
between auto transmissions.
This gives a theoretical reading rate from 17578 per
sec to 1 per sec. (i.e. rate=52734/P20). Practically, the
actual rate for low values of P20 is usually less than
the theoretical rate. (“P20” stands for “Parameter
#20”.) Note that this rate relates to USB
communication; upon using a serial port, the rate is far
smaller.

Becomes effective only after a system reset (either

power off/on or using the ‘S’ command).

Float

Advertising