Omega Speaker Systems High Speed Load Cell Interface Card LCIC-WIM-BEN User Manual

Page 33

Advertising
background image

32

i. Misc.:

z (lower case z)

Manually zero the gross weight. The effect of this function
is temporary — it expires upon card reset.
Response (versions 1.12, 3.09, 6.01, 7.00 and up):
‘z’<c/r>.

Z (Upper case Z)

(versions 1.12, 3.09,

6.01, 7.00 and up)

Cancel the manual zero operation (the lower case ‘z’).
That is, return to the original calibration zero.
Response: ‘Z’<c/r>.

S

(upper case S)

System reset (software reset to perform a restart as if
turned off/on).
Response (versions 1.12, 3.09, 6.01, 7.00 and up):
‘S’<c/r> - possibly followed by additional binary
character(s).
Wait 6 seconds before accessing the board again.

Issue this command after changing any of the following

parameters:

* Auto transmit interval (parameter #20).

* Filters & Decimators (parameters #23-25).

* General Setpoints (parameters #101-104).

* Output modes (parameters #111-114).

F (upper case F)

Start Fill-mode.

V (upper case V)

Get version no. of DSP software.
Board’s response: “

LCIC-WIM/

V#.##”, where

#.## = Version Number.