c. Get a single reading of:

weight, A/D or temperature:

.

Get weight (after Filter2, not rounded to resolution).

?

Get weight (after Filter2, rounded to resolution).

>

Get A/D reading after Filter1.

<

Get A/D reading after Filter2.

T

Get temperature

d. Analog output: Read & write voltage:

@

Gets the analog output voltage (in Volts).

v

x

<c/r>

(lower case v)

Sets the analog output voltage to

x

Volts.

The analog output voltage is measured at pin 12 of CONN6

with respect to pin 13 which is ground.

e. Digital Outputs: Write outputs:

a

Turn on Output1 if Manual

A

Turn off Output1 if Manual

b

Turn on Output2 if Manual

B

Turn off Output2 if Manual

c

Turn on Output3 if Manual

C

Turn off Output3 if Manual

d

Turn on Output4 if Manual

D

Turn off Output4 if Manual

f. Digital Outputs: Read outputs:

O

(upper case o)

Card returns a string of the form ‘

xxxx

<c/r>’, where

x

is

either “1” or “0” representing the status of the 4 output
opto relays OUT4,OUT3,OUT2,OUT1 respectively.

g. Digital Inputs: Read inputs & toggling counter:

I

(upper case i)

Card returns a string of the form '

xxxx

<c/r>’, where

x

is

either “1” or “0” representing the digital input status of
IN4,IN3,IN2,IN1 respectively.

i

Gets a 16 bit ‘toggling counter’. The ‘toggling counter’

increments each time when input #2 is toggled.