Straight out, 45 degree, Cb 1200 pellet stove – Quadra-Fire CB1200M-MBK User Manual

Page 14: B. through the wall

Advertising
background image

Page 14

7014-179D

December 16, 2011

R

CB 1200 Pellet Stove

6 in.

(152mm)

Minimum

Non-combustible Hearth Pad

W all

Thimble

Horizontal

T ermination

Cap

2 in.

(51mm)

Minimum

6 in.

(152mm)

Minimum

From Glass

Straight Out

B. Through The Wall

Horizontal termination cap must be a minimum of 12 inches.

(305mm) from the wall. Approved for mobile home instal-

lations. Must use 3 or 4 inch (76-102mm) “L” or “PL” listed

pellet venting or listed double wall pipe and a Quadra-Fire

outside air kit in mobile homes.

NOTE:

In Canada, where passage through a wall or partition of

combustible construction is desired, the installation shall

conform to CAN/CSA-B365

Figure 14.1

Figure 14.2

Wall

Thimble

Illustration shows venting going in both directions.

Choose which one is best for your installation.

2 in. (51mm)

Minimum

2 in. (51mm)

Minimum

6 in.

(152mm)

Minimum

6 in. (152mm)

Minimum

45 Degree

NOTICE:

Please note that while the minimum

clearance for the termination cap is 6

inches (152mm) there is the possibly

of soot buildup around the termina-

tion area. If this occurs we suggest

to move the termination further away

from the house to prevent it.