7014-179D

December 16, 2011

R

CB 1200 Pellet Stove

1

Listing and Code Approvals

A. Appliance Certification

C. Glass Specifications

E. BTU & Efficiency Specifications

This appliance is equipped with 5mm ceramic glass. Replace

glass only with 5mm ceramic glass. Please contact your

dealer for replacement glass.

B. Mobile Home Approved

NOTE: This installation must conform with local codes.

In the absence of local codes you must comply with the

ASTM E1509-95, ULC S627-M93, ULC/ORD-C-1482-

M1990, (UM) 84-HUD

D. Electrical Rating

115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 Amps

*BTU output will vary, depending on the brand of fuel you

use in your stove. Consult your Quadra-Fire dealer for

best results.

NOTE: Hearth & Home Technologies, manufacturer of

this appliance, reserves the right to alter its products,

their specifications and/or price without notice.

Emissions Rating

0.

.

9 grams/hr

*BTU Output

14,000 - 40,000 / hr

Heating Capacity

up to 2,500 sq. ft. depending

on climate zone

Hopper Capacity

80 lbs

Fuel

Wood Pellets or Shelled Corn

Shipping Weight

349 lbs

Model

CB1200 Pellet Stove

Laboratory

OMNI Test Laboratories, Inc.

Report No.

061-S-21-4

Type

Solid Fuel Room Heater/Pellet Fuel
BurningType

Standard

ASTM E1509-95, ULC S627-M93 and
ULC/ORD-C1482-M1990 Room Heater
Pellet Fuel Burning type and (UM) 84-
HUD, Mobile Home Approved.

State Listing Colorado, Listed 09-13-05

NOTE: Some generator or battery back-up systems

may not be compatable with the micro-processor elec-

tronics on this appliance. Please consult the power

supply manufacturer for compatable systems.

WARNING! Risk of Fire! Hearth & Home Technologies

disclaims any responsibility for, and the warranty and agency

listing will be voided by the above actions.
DO NOT:

• Install or operate damaged appliance

• Modify appliance

• Install other than as instructed by Hearth & Home

Technologies

• Operate the appliance without fully assembling all

components

• Overfire

• Install any component not approved by Hearth &

Home Technologies

• Install parts or components not Listed or approved.

Improper installation, adjustment, alteration, service or

maintenance can cause injury or property damage.
For assistance or additional information, consult a qualified

installer, service agency or your dealer.

Quadra-Fire is a registered trademark of Hearth & Home

Technologies.

This appliance is approved for mobile home installations

when not installed in a sleeping room and when an outside

combustion air inlet is used.
The structural integrity of the mobile home floor, ceiling, and

walls must be maintained.
The appliance must be properly grounded to the frame of

the mobile home and use only Listed pellet vent Class “L”

or “PL” connector pipe.
A Quadra-Fire Outside Air Kit must be installed in a mobile

home installation. You must order the Outside Air Kit sepa-

rately.

Note: The appliance is also approved for installation

into a shop.