Quadra-Fire QV-PIER User Manual

Page 18

Advertising
background image

18

Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06

Figure 8

NOTE: On vertical venting
configurations you may
want to install the flue re-
strictor (385-128). See flue
restrictor installation in-
structions.

Flue Restrictor Instructions

1. Locate the flue restrictor which is in the manual

bag.

Figure 9

2. Break the Flue Restrictor into two pieces. Do this

by bending the part back and forth until it breaks
(see Figure 10).

V

CAP

FLUE

RESTRICTOR

STRAIGHT UP

VERTICAL VENTING

V (FT.)

50' MAX. (15.2 M)

Figure 10. Flue Restrictor

BREAK

HERE

1 2 3 4 5

SETTINGS

1 2 3 4 5

4. Center the Flue Restrictor on vent and secure in

place using two self-tapping screws (see Figure 11).

STRAIGHT OUT

HORIZONTAL VENTING

H

Max. Run

24" (610 mm)

Figure 12.

H

3. Match the amount of

vertical you have in the
system with the chart to
find the appropriate po-
sition to set the Flue Re-
strictor.

Figure 11

- CHART -

Vertical

Settings

4'

1-1

8'

1-2

15'

2-2

20'

2-3

25'

3-3

30'

4-3

35'

4-4

40'

4-4

50'

4-5