Quadra-Fire QV-PIER User Manual

Page 20

Advertising
background image

20

Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06

Figure 15. Venting with Two 90° Elbows

H

1

H

V

V

V

1

H

NATURAL GAS

VENTING WITH TWO 90° ELBOWS

V (FT.)

H + H

1

(FT.)

90

0

Elbow on top 2.5’ MAX. (64mm)

1' MIN. (305mm)

3' MAX. (914mm)

2' MIN. (610mm)

6' MAX. (1.83m)

3' MIN. (914mm)

9' MAX. (2.7m)

4' MIN. (1.22m)

12' MAX. (3.6m)

5’ MIN. (1.5m)

15’ MAX. (4.5m)

6’ MIN. (1.83m)

18’ MAX. (5.5m)

V + H + H

1

= 50’ MAX. (15.2m)

PROPANE

VENTING WITH TWO 90° ELBOWS

V (FT.)

H + H

1

(FT.)

90

0

Elbow on top 2’ MAX. (610mm)

1' MIN. (305mm)

2' MAX. (610mm)

2' MIN. (610mm)

4' MAX. (1.22m)

3' MIN. (914mm)

6’ MAX. (1.83m)

4' MIN. (1.22m)

8' MAX. (2.4m)

5’ MIN. (1.5m)

10' MAX. (3.0m)

6’ MIN. (1.83m)

12' MAX. (3.6m)

V + H + H

1

= 50’ MAX. (15.2m)

NATURAL GAS

VENTING WITH TWO 90° ELBOWS

V + V

1

(FT.)

H (FT.)

90

0

Elbow on top 2.5’ MAX. (64mm)

1' MIN. (305mm)

3' MAX. (914mm)

2' MIN. (610mm)

6' MAX. (1.83m)

3' MIN. (914mm)

9' MAX. (2.7m)

4' MIN. (1.22m)

12' MAX. (3.6m)

5’ MIN. (1.5m)

15’ MAX. (4.5m)

6’ MIN. (1.83m)

18’ MAX. (5.5m)

V + V

1

+ H = 50’ MAX. (15.2m)

PROPANE

VENTING WITH TWO 90° ELBOWS

V + V

1

(FT.)

H (FT.)

90

0

Elbow on top 2’ MAX. (610mm)

1' MIN. (305mm)

2' MAX. (610mm)

2' MIN. (610mm)

4' MAX. (1.22m)

3' MIN. (914mm)

6’ MAX. (1.83m)

4' MIN. (1.22m)

8' MAX. (2.4m)

5’ MIN. (1.5m)

10' MAX. (3.0m)

6’ MIN. (1.83m)

12' MAX. (3.6m)

V + V

1

+ H = 50’ MAX. (15.2m)

H + H

1

= 18’ MAX. (5.5m)

H + H

1

= 12’ MAX. (3.6m)

Advertising