Figure 18. venting with three 90° elbows – Quadra-Fire QV-PIER User Manual

Page 22

Advertising
background image

22

Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06

Figure 18. Venting with three 90° elbows

H

H

1

H

2

V

H

V

H

1

V

1

NATURAL GAS

VENTING WITH THREE 90° ELBOWS

V + V

1

(FT.)

H + H

1

(FT.)

1' MIN. (305mm)

3' MAX. (914mm)

2' MIN. (610mm)

6' MAX. (1.83m)

3' MIN. (914mm)

9' MAX. (2.7m)

4' MIN. (1.22m)

12' MAX. (3.6m)

5’ MIN. (1.5m)

15’ MAX. (4.5m)

6’ MIN. (1.83m)

18’ MAX. (5.5m)

V+ V

1

+ H + H

1

= 50’ MAX. (15.2m)

PROPANE

VENTING WITH THREE 90° ELBOWS

V + V

1

(FT.)

H + H

1

(FT.)

1' MIN. (305mm)

2' MAX. (610mm)

2' MIN. (610mm)

4' MAX. (1.22m)

3' MIN. (914mm)

6’ MAX. (1.83m)

4' MIN. (1.22m)

8' MAX. (2.4m)

5’ MIN. (1.5m)

10' MAX. (3.0m)

6’ MIN. (1.83m)

12' MAX. (3.6m)

V+ V

1

+ H + H

1

= 50’ MAX. (15.2m)

H + H

1

= 12’ MAX. (3.6m)

H + H

1

= 18’ MAX. (5.5m)

NATURAL GAS

VENTING WITH THREE 90° ELBOWS

V + V

1

(FT.)

H + H

1

+ H

2

(FT.)

1' MIN. (305mm)

3' MAX. (914mm)

2' MIN. (610mm)

6' MAX. (1.83m)

3' MIN. (914mm)

9' MAX. (2.7m)

4' MIN. (1.22m)

12' MAX. (3.6m)

5’ MIN. (1.5m)

15’ MAX. (4.5m)

6’ MIN. (1.83m)

18’ MAX. (5.5m)

V+ V

1

+ H + H

1

+ H

2

= 50’ MAX. (15.2m)

PROPANE

VENTING WITH THREE 90° ELBOWS

V + V

1

(FT.)

H + H

1

+ H

2

(FT.)

1' MIN. (305mm)

2' MAX. (610mm)

2' MIN. (610mm)

4' MAX. (1.22m)

3' MIN. (914mm)

6’ MAX. (1.83m)

4' MIN. (1.22m)

8' MAX. (2.4m)

5’ MIN. (1.5m)

10' MAX. (3.0m)

6’ MIN. (1.83m)

12' MAX. (3.6m)

V+ V

1

+ H + H

1

+ H

2

= 50’ MAX. (15.2m)

H + H

1

+ H

2

= 12’ MAX. (3.6m)

H + H

1

+ H

2

= 18’ MAX. (5.5m)