Quantum Data 882E User Manual

Page 10

Advertising
background image

9

882E Quick Start Guide - HDCP Compliance Testing with Encryption Status Tester (EST) - P/N 68-00210 Rev. B

7. Select

HDCP to access the HDCP compliance test menu.

The following is displayed on the generator’s LCD.

8. Select

EditPCP to define the capabilities of the HDCP device under test.

The following is displayed on the generator’s LCD.

The following table describes the test parameters and their settings (gray = N/A).

Parameter

Explanation

DUT type

Specifies the type of device under test. This can be one
of Sink, Source, Repeater, Repeater3AB, or
Repeater3C. For this test, select Source.

Source Max KSV

Specifies the maximum number of KSVs the source can
read. The valid values are 1 through 127.

Source Authentication Control

Specifies the number of times a source DUT attempts
authentication before transitioning into the authentica-
tion state. The valid values are 1 or greater.

Source Out Only Repeater

Indicates whether the DUT outputs contents to a
repeater to which no downstream device is connected.
The values are + for yes and - for no.

Sink 1.1 Features Supported

Indicates whether the DUT supports Advanced_Cipher
mode and Enhanced Link Verification. The values are +
for yes and - for no.

Sink 1.1 Audio Supported

Indicates whether the DUT supports audio output. The
values are + for yes and - for no.

Repeater 1.1 Features Supported

Indicates whether supports Advanced_Cipher mode
and Enhanced Link Verification. The values are + for yes
and - for no.

Repeater Audio Support

Indicates whether the DUT supports audio output. The
values are + for yes and - for no.

Repeater HPD Pulse

Indicates whether the DUT has the capability to output
HPD pulse by user operation. The values are + for yes
and - for no.

!CompRpt

EditPCP

Source

:DUT Type

0

1
+Source_Out_OnlyRep

:Source_Authe_Cnt

:Source_Max_KSV