Quantum Data 882E User Manual

Page 35

Advertising
background image

34

882E Quick Start Guide - HDCP Compliance Testing with Encryption Status Tester (EST) - P/N 68-00210 Rev. B

9. Select

Repeater3C device by pressing the adjacent soft key to specify that the device

under test is a repeater.

The following is displayed on the generator’s LCD.

Alternatively, you can specify the device under test as a repeater for the 3C test using
the following commands:

CPTX:DUTT 4

// specifies the device under test as a repeater

for the 3C test.

You can query the current value of the parameter with:

CPTX:DUTT?

// returns the device under test type.

10. (Optional) Specify the remaining parameters in the

EditPCP menu using the table

above.

Alternatively, you can specify the parameters through the command line as follows:

CPTX:RPFT 0

// indicates whether DUT (repeater) supports 1.1

features such as Advanced Cipher and Enhanced
Link Verification. 1 = yes; 0 = no.

CPTX:RKSV 10

// specifies maximum number of downstream devices

that can be supported in the repeater’s KSV list

CPTX:ROOR 0

// indicates whether DUT (repeater) outputs outputs

content to the downstream repeater that does not
have any downstream device connected.
1 = yes; 0 = no.

11. Press the

Options key to save the capabilities definition.

The generator LCD will display the message “Saved”.

12. Press the

Tools key get back to the Reports menu.

The generator LCD will display the reports menu as shown below.

13. Select

HDCP to access the HDCP compliance test menu.

The following is displayed on the generator’s LCD.

Repeater3C

:DUT Type

0

1
+Source_Out_OnlyRep

:Source_Authe_Cnt

:Source_Max_KSV

EDID

Packets

Misc

HDCP

!CompRpt

EditPCP

Advertising