Quantum Data 882E User Manual

Page 18

Advertising
background image

17

882E Quick Start Guide - HDCP Compliance Testing with Encryption Status Tester (EST) - P/N 68-00210 Rev. B

CPTX:DUTT 0

// specifies the device under test as a sink.

You can query the current value of the parameter with:

CPTX:DUTT?

// returns the device under test type.

8. (Optional) Specify the remaining parameters in the

EditPCP menu using the table

above.

Alternatively, you can specify the parameters through the command line as follows:

CPTX:SRFT 0

// indicates whether DUT (sink) supports 1.1

features such as Advanced Cipher and Enhanced
Link Verification. 1 = yes; 0 = no.

9. Press the

Options key to save the capabilities definition.

The generator LCD will display the message “Saved”.

10. Press the

Tools key get back to the Reports menu.

The generator LCD will display the reports menu as shown below.

11. Select

HDCP to access the HDCP compliance test menu.

The following is displayed on the generator’s LCD.

12. Select

!CompRpt to initiate the HDCP compliance test.

The message “HDCP Compliance Test” is shown and then all the tests are shown in
sequence.

Alternatively, you can run the tests using the following command:

CPTX:CPTR 46

// specifies that all applicable tests will be run.

CPTX:CPTU

// Initiates the execution of the test

Refer to

To view the HDCP compliance report:

” on page 42 for procedures on how to

view the generated report.

EDID

Packets

Misc

HDCP

!CompRpt

EditPCP

Advertising