Quantum Data 882E User Manual

Page 12

Advertising
background image

11

882E Quick Start Guide - HDCP Compliance Testing with Encryption Status Tester (EST) - P/N 68-00210 Rev. B

14. Select

HDCP to access the HDCP compliance test menu.

The following is displayed on the generator’s LCD.

15. Select

!CompRpt to initiate the HDCP compliance test.

The message “HDCP Compliance Test” is shown and then all the tests are shown in
sequence.

Refer to

To view the HDCP compliance report:

” on page 42 for procedures on how to

view the generated report.

Alternatively, you can run the tests using the following command:

CPTX:CPTR 46

// specifies that all applicable tests will be run.

CPTX:CPTU

// Initiates the execution of the test

16. Monitor the LCD for a set of prompts during the 1A-01, 1A-09, and 1B-01 tests. When

prompted with the screen shown below, examine the video on the display under test
and press the appropriate button adjacent to the indication (Yes! or No!) to continue.

Note: The prompt asks you if the video appearing on the connected display looks
good. “Looks good” means that there is a picture and an absence of excessive snow.

17. (Optional) To run a specific test with the generator as

sink (1A tests), you can use the

command line as shown below:

CPTX:CPTR 1

// Selects specific test (e.g. 1A_01) see table below

CPTX:CPTU

// Initiates the execution of the test.

You can query the complete list of tests to choose from:

CPTX:GCTN?

// Queries the list of tests supported

You can query the currently selected test to run with:

CPTX:CPTR?

// Queries the selected test to run (see table)

18. (Optional) To run a specific test with the generator as

repeater (1B tests), you can use

the command line as shown below:

CPTX:CPTR 10

// Selects specific test (e.g. 1B_01) see table below

CPTX:CPTU

// Initiates the execution of the test.

You can query the complete list of tests to choose from:

!CompRpt

EditPCP

Does the video look
good?

!Yes No!

Advertising