Maintenance – Tiger Products Co., Ltd JD 5065 / 5085 - 5105M User Manual

Page 108

Advertising
background image

MAINTENANCE

SIDE ROTARY

Maintenance Section 4-12

© 2012 Alamo Group Inc.

MAINTENANCE

RECOMMENDED FILLING INSTRUCTIONS FOR HYDRAULIC
RESERVOIRS

When filling or checking the oil level, the unit should
be parked on a level surface., shut “OFF”, and
allow sufficient time to cool to ambient temperature.
Use caution when removing the pressurized
breather. Do not place face over opening when
removing breather.

If your reservoir has two sight glasses: The
reservoir should be filled to the top of the lower
sight glass on the side of the tank. Do not over-fill.
The reservoir has been over-filled when oil is visible
in the upper sight glass. If tank has too much oil, the
excess may be expelled through the pressurized
breather.

If your reservoir has one sight glass/temperature
gage: The reservoir should be filled to the center
of the sight glass on the side of the tank. Do not
over-fill. If the tank has too much oil, the excess
may be expelled through the pressurized breather

REPLACING IN-TANK HYDRAULIC FILTER

Loosen the four bolts on the top cover of the filter
housing. Turn cover counter-clockwise until cover is
free. Remove and replace filter. Replace top cover
and cover bolts in opposite order as removed.

Advertising