10.0 - Service Procedures

The following procedures are based upon having access to the steamer on all four sides. If the steamer is installed

between other appliances and there is not enough room on the sides for access, the steamer must then be pulled out

from its position to gain proper access.

Care should be taken in moving the steamer so as not to stress or pull on the electrical and water connections.

10.1

Top Right Side Panel (Louvered) - Removal

P/N 123183

1. With a flat blade screw driver remove the two 10-32

screws on the lower edge and one screw on the top

edge of the panel. The panel is held to the steamer

by two spring-like clips at the rear and bottom edge.

2. Once the screws are removed SLIDE the panel

towards the front with a lifting motion. Do not attempt

to PRY the panel. Once the panel is free of the rear

and lower clips, it may be lifted off.

ASSEMBLY TIP: When replacing the panel, press the

rear edge inward so that both clips will be retained by the

back flange. Make sure that the holes in the panel are in

alignment with the tapped holes in the steamer so that

the replacement of the two 10-32 screws will be easy and

not damage the screws.

10.2

Steamer Table Panels

Front P/N 096720

Rear P/N 096785

Left/Right Side P/N 096848

1. To remove the steamer table lower panel, simply

raise the panel and swing out. There are no fasteners

on this panels and it is retained only by upper and

lower tracks.

2. To remove the front and side panels remove the

screw(s) holding the panel, then remove the panels.

3. The front and rear panels are unique and the two

side panels are identical and interchangeable.

10.3

Left Side - Removal

P/N 123184

Under normal conditions, the left side cover should never

have to be removed as there are no operational and/or

replacement parts to be accessed. The single exception

is if the door has been reversed so that the handle is on

the LEFT and the Door Interlock Switch is found to be

defective and must be replaced. The door switches for

BOTH door positions are installed at the time of

manufacture, so there is no need to access the switch if

the door is to be reversed.

1. If the top/left side cover must be removed due to a

faulty door switch, remove the right side panel (as

above) first. Then remove the top left panel in the

same manner.

10.4

Adjustable Legs

P/N 042505

1. Each leg is provided with a screw type support post.

These may be extended or retracted by turning them

with a wrench or ChannelLock. Make sure that all

four legs are in tight contact with the floor for proper

steamer support.

2. If damaged, these posts may be replaced by tapping

out (on opposite sides of the leg) the threaded fitting

which is friction held in each stainless steel leg. The

stainless leg and the threaded fitting are one

assembly.

NOTE: The following components and assemblies are to

be found in the lower table portion of the steamer.

10.5

Steam Generator Drain Valve

P/N 071234

1. Turn off power and allow steamer to drain

completely. Remove back cover panel and loosen

hose clamps.

2. Disconnect both ends of the drain hose from the

spray box and the steam generator.

3. Unplug and disconnect the valve electrical wires.

Remove the nuts holding the valve to the plate.

Remove the valve from the threaded studs. Then

remove the silicone hose from the valve.

4. Inspect the silicone hose for any damage or lime

buildup. Replace hose if required.

5. Attach new drain valve to valve bracket. Pull silicone

hose through drain valve and loosely install hose

clamps over both ends of the hose. Be sure silicone

hose is properly aligned and does not have any

kinks, bends and/or twists.