6 OM/SM-HY-6G(CE)

OM/SM-HY-6G(CE)

6

4.0 - Installation, Start-Up and Conversion

WARNING

THE UNIT MUST BE INSTALLED BY PERSONNEL WHO ARE QUALIFIED TO WORK WITH ELECTRICITY AND

PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE

EQUIPMENT. THE UNIT MUST BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES.

CAUTION

DO NOT INSTALL THE UNIT WITH THE RIGHT SIDE VENTS BLOCKED OR WITHIN 30 CENTIMETERS OF

A HEAT SOURCE (SUCH AS A BRAISING PAN, DEEP FRYER, CHAR BROILER, OR KETTLE).

TO AVOID DRAINAGE PROBLEMS, LEVEL THE UNIT FRONT TO BACK, OR PITCH IT SLIGHTLY TO THE

REAR.

4.1 General

4.1.1

Model Number and Dimensions

MODEL

WIDTH

mm (in.)

DEPTH

mm (in,)

HEIGHT

mm (in.)

WEIGHT

Kg (lbs)

HY-6G(CE)

549

(21.6)

894

(35.2)

1464

(57.6)

193

(425)

4.1.2

Siting and Clearances

The HY-6G(CE) steamer is suitable for installation in

combustible and noncombustible locations.

Minimum clearances for installation are:

Right Side

300 mm (12 inches)

Left Side

0 mm (0 inches)

Rear of Flue

150 mm (6 inches)

However, for easy service at least

300 mm (12

inches) clearance is required for the right side of

the unit, and it may

not be installed within 300 mm

(12 inches) of a heat source, as stated in the

Caution above.

The unit must be installed in a well-ventilated room

with an adequate air supply. The steamer must be

installed beneath a ventilation hood, since gas

combustion products exit the appliance.

Any item which might obstruct or restrict the flow of

air for combustion and ventilation must be removed.

Do not obstruct the flue cover or any front, side, rear,

or top vents after installation.

The area directly around the appliance must be

cleared of all combustible material. The installation

must conform with local codes or, in the absence of

local codes, with the National Fuel Gas Code, ANSI

Z223.1, latest edition, including the following:

The unit and its individual shutoff valve must be

disconnected from the gas supply system during

any pressure testing of that system at test pressures

in excess of ½ PSI (3.45 kPa). It must be isolated

from the gas supply piping system by closing its

individual manual shutoff valve during any pressure

testing of the gas supply piping system at test

pressures

equal to or less than ½ PSI (3.45 kPa).

4.2 Electrical Supply Connection

The unit is designed for connection to fixed wiring. A

suitably rated isolating switch with contact separation

of at least 3 mm on both poles must be fitted to the

installation. Wiring must be executed in accordance

with the regulations listed on page 2 of this manual.

Cable entry is at the bottom rear right side of the

appliance. To gain access the panel must be

removed. Open the lower front panel by removing its

screws. Lift the panel and swing its bottom toward

you. Set the panel aside.

Provide 230 Volt, 50 Hz, Single Phase, 15 Ampere

service. Maximum load is 2½ amps. The electrical

schematic is located in the service compartment. A

copy is also printed at the rear of this manual.

CAUTION

THE UNIT MUST HAVE A SEPARATE EARTHING

WIRE FOR SAFE OPERATION.

4.3 Gas Supply Connection

Incoming service must be of sufficient size to supply

full rate without excessive pressure drop. A gas

meter is connected to the service pipe by the Gas

Supplier. Any existing meter should be checked out

by the Gas Supplier to ensure that it has adequate

capacity to provide the required rate of gas to the

steamer, in addition to any other equipment.