Om/sm-hy-6g(ce) – Unified Brands HYPERSTEAM HY-6G(CE) User Manual

Page 7

Advertising
background image

OM/SM-HY-6G(CE) 

OM/SM-HY-6G(CE)

7

Gas input is through a ½ inch B.S.P.T connection

at the left rear of the unit.

GAS INPUT RATE BTU/HR AND KW

HY-6G(CE)

Natural Gas

9.25 mBar

(3.7 in. W.C)

Propane Gas

26.25 mBar

(10.5 in. W.C.)

Individual

Steamer Cavity

40950 BTU/hr

12 KW

40950 BTU/hr

12 KW

Total

Both Cavities

81900 BTU/hr

24 KW

81900 BTU/hr

24 KW

Installation pipe work must be fitted in accordance with

IGE/UP/2.

The appliance governor is suitable for both natural and

propane gas without conversion. The governor is

incorporated in the gas control valve, which is inside the

control cabinet.

Connection to the gas supply can be completed with ½”

B.S.P.T. pipe. Although the immediate connection to the

appliance is ½” B.S.P.T., gas supply piping must be large

enough to provide 90,000 BTU/hour. Minimum supply

pressure must be 20 mBar for natural gas, or 37 mBar

for propane gas.

An isolating cock must be located close to the appliance

to allow shut down in an emergency, or for servicing.

The installation must be tested for gas soundness and

purged as specified in IGE/UP/1.

4.3.1

Gas Pressure Adjustment

Gas pressure has been set at the factory but should be

checked by connecting a manometer to the pressure tap

on the burner manifold. The adjusted gas pressures is

shown in the table below.

G20 Natural Gas

G31 Propane Gas

mBar

Inch W.C.

mBar

Inch W.C.

9.25

3.7

26.25

10.5

If necessary, the gas pressure may be readjusted as

described in the Service Manual.

NOTE: With reference to gas rate, pressure adjustments

and conversions, this appliance is CE-approved for use

with C20 natural gas and G31 propane gas in Ireland

and the United Kingdom.

Use of the appliance with non-approved gases in a listed

country, or use in other countries, will void CE

certification.

4.3.2

Injector Diameters

Natural Gas

Propane Gas

Injector

Dia. (mm)

No. of

Injectors

Injector

Dia. (mm)

No. of

Injectors

Main

Burner

1.49

4 x 2

0.94

4 x 2

Standby

Burner

0.99

1 x 2

0.57

1 x 2

Pilot

Burner

0.60

1

0.25

1

4.3.3

Burner Air Adjustment

The unit is equipped with fixed aeration type burners

which have no provision for air inlet adjustment.

4.3.4

Equipotential Terminal

In accordance with national regulations, each unit is

fitted with an equipotential terminal.

4.4 Water Supply Connection

The HY-6G CE model is fitted for a 3/4 inch B.S.P.T.

cold water connection. The water supply must be

provided at a rate of not less than 2.7 liters (0.70

gallons) per minute. Pressure must be 2.0 to 4.0 Bar

(30 to 60 PSI) maximum.

Water quality minimums require totally dissolved

solids (T.D.S.) of 30 parts per million maximum, and

a water pH of 7.0 or greater. If the available water

supply fails to meet these requirements, water

treatment equipment must be provided to ensure

steamer reliability and operating life.