Om/sm-hy-6g(ce) – Unified Brands HYPERSTEAM HY-6G(CE) User Manual

Page 32

Advertising
background image

 OM/SM-HY-6G(CE)

OM/SM-HY-6G(CE)

32

18. The wires for the alternate door switch may be

foundunder the cavities. Connect the two wires from

the switch to the wiring harness.

19. Close steamer door and operate steamer for six to

eight minutes. If steamer fan does not operate,

check location of door magnet and try operation

again. If fan operation problem still exists, refer to

the Troubleshooting Section of this Manual.

20. Allow steamer to operate for approximately 5

minutes, and then check for leaks. If there are no

leaks then steamer is ready for operation. If there

are leaks around the door, recheck door alignment,

and if necessary, door gasket installation.

10.27

Door Gasket

P/N 094147

1. To install, turn off steamer, and allow to cool.

2. Remove the door hinge using one of the following

two methods:

a)

Support door weight and remove hinge pin, or

b)

Support weight of the door and remove the two

door-to-hinge bolts.

3. Place the door on a flat, clean, smooth table or

similar support. Be careful not to scratch the door

4. Position door on workbench so that its front is lying

flat, with handle hanging over edge of bench.

5. Remove inner door panel.

6. Remove and discard gasket.

7. Clean back of the inner door panel. Be sure old

sealant is completely removed.

8. Install new door gasket around inner door panel. Be

sure the inner door panel flange is fully inserted into

the door gasket groove.

9. Apply a high temperature silicone sealant, such as

GE RTV 180 or equivalent, to the four door spacers.

10. Apply Locktite 242 to the inner door panel mounting

screws.

11. Install inner door panel and door gasket on the door

spacers, and tighten mounting screws.

12. Align door with hinge and insert hinge pin OR apply

Locktite 242 to the door-to-hinge bolts, then install

door and mounting bolts. Do NOT tighten mounting

bolts at this time.

13. Align door to steamer, per Paragraph 10.24..

10.28

Door Handle, Magnet and Block Assembly

Door Handle

P/N 070123

Magnet & Block P/N 069762

Screws

P/N 005764

Door Cam

P/N 074252

U-Channel Assy

P/N 094144

Outer Door Panel P/N 094140

Inner Door Panel P/N 094141

Door Insulation Bd P/N 094192

1. Turn steamer off and allow it to cool.

2. Remove screws and U-channel from the door.

3. Remove screws securing handle, door handle, and

cam.

4. Apply a NEVER-SEEZ high temperature compound

to the door cam and Locktite 242 to screw threads.

5. Assemble door cam to handle with screws.

6. Be sure door handle is in the DOWN position. Hold

U-channel door spring open with a screwdriver or

similar tool, then install the U-channel. Do NOT

install screws at this time

7. Check operation of the cam and door spring. Push

up on the door handle and check if spring opens. If

the spring does not open, the cam and spring are not

correctly aligned and the problem must be corrected.

8. Apply a light amount of Locktite 242 to screws, then

install screws, securing U-channel.

10.29

Door Spring

P/N 078911

1. Turn off steamer and allow it to cool.

2. With flat blade screwdriver, remove two screws on

U-channel and remove U-channel from door.

3. Carefully remove retaining ring from one end of

spring support pin, then remove the pin by moving

the pin to the left and to the right.

4. With a wrench, remove the nut. Lift the spring

retainer, and then remove the spring.

To Install:

5. Apply a high temperature (rated 250ºC) anti-seize,

lubricating compound (NEVER-SEEZ) on the bottom

of the U-channel surface that contacts the spring.

Advertising