Om/sm-hy-6g(ce) – Unified Brands HYPERSTEAM HY-6G(CE) User Manual
Page 32
OM/SM-HY-6G(CE)
OM/SM-HY-6G(CE)
32
18. The wires for the alternate door switch may be
foundunder the cavities. Connect the two wires from
the switch to the wiring harness.
19. Close steamer door and operate steamer for six to
eight minutes. If steamer fan does not operate,
check location of door magnet and try operation
again. If fan operation problem still exists, refer to
the Troubleshooting Section of this Manual.
20. Allow steamer to operate for approximately 5
minutes, and then check for leaks. If there are no
leaks then steamer is ready for operation. If there
are leaks around the door, recheck door alignment,
and if necessary, door gasket installation.
10.27
Door Gasket
P/N 094147
1. To install, turn off steamer, and allow to cool.
2. Remove the door hinge using one of the following
two methods:
a)
Support door weight and remove hinge pin, or
b)
Support weight of the door and remove the two
door-to-hinge bolts.
3. Place the door on a flat, clean, smooth table or
similar support. Be careful not to scratch the door
4. Position door on workbench so that its front is lying
flat, with handle hanging over edge of bench.
5. Remove inner door panel.
6. Remove and discard gasket.
7. Clean back of the inner door panel. Be sure old
sealant is completely removed.
8. Install new door gasket around inner door panel. Be
sure the inner door panel flange is fully inserted into
the door gasket groove.
9. Apply a high temperature silicone sealant, such as
GE RTV 180 or equivalent, to the four door spacers.
10. Apply Locktite 242 to the inner door panel mounting
screws.
11. Install inner door panel and door gasket on the door
spacers, and tighten mounting screws.
12. Align door with hinge and insert hinge pin OR apply
Locktite 242 to the door-to-hinge bolts, then install
door and mounting bolts. Do NOT tighten mounting
bolts at this time.
13. Align door to steamer, per Paragraph 10.24..
10.28
Door Handle, Magnet and Block Assembly
Door Handle
P/N 070123
Magnet & Block P/N 069762
Screws
P/N 005764
Door Cam
P/N 074252
U-Channel Assy
P/N 094144
Outer Door Panel P/N 094140
Inner Door Panel P/N 094141
Door Insulation Bd P/N 094192
1. Turn steamer off and allow it to cool.
2. Remove screws and U-channel from the door.
3. Remove screws securing handle, door handle, and
cam.
4. Apply a NEVER-SEEZ high temperature compound
to the door cam and Locktite 242 to screw threads.
5. Assemble door cam to handle with screws.
6. Be sure door handle is in the DOWN position. Hold
U-channel door spring open with a screwdriver or
similar tool, then install the U-channel. Do NOT
install screws at this time
7. Check operation of the cam and door spring. Push
up on the door handle and check if spring opens. If
the spring does not open, the cam and spring are not
correctly aligned and the problem must be corrected.
8. Apply a light amount of Locktite 242 to screws, then
install screws, securing U-channel.
10.29
Door Spring
P/N 078911
1. Turn off steamer and allow it to cool.
2. With flat blade screwdriver, remove two screws on
U-channel and remove U-channel from door.
3. Carefully remove retaining ring from one end of
spring support pin, then remove the pin by moving
the pin to the left and to the right.
4. With a wrench, remove the nut. Lift the spring
retainer, and then remove the spring.
To Install:
5. Apply a high temperature (rated 250ºC) anti-seize,
lubricating compound (NEVER-SEEZ) on the bottom
of the U-channel surface that contacts the spring.