3.0 - Water Conditioning

It is essential to supply the steam generator with

water that will not form scale. Even though the steam

generator is engineered to minimize scale formation,

scale development depends on the hardness of your

water and the number of hours the equipment

operates.

In some areas of the country, water is low enough in

minerals to avoid scale formation. But most water

supplies are full of minerals which form scale. It is

this scale which could lead to an early component

failure.

Your water utility can tell you about the minerals in

your water. The water going to the steam generator

should have between 10 and 30 parts per million

(ppm) total dissolved solids (TDS) and should have a

pH (acidity rating) of 7.0 or higher. Please follow these

simple precautions:

3.1 Do not

rely on unproven water treatments

which are sold as scale prevention or scale

removers.

They don’t always work. The best

way to prevent scale is to supply the purest

possible water (10 - 30 ppm TDS).

3.2 If your water contains scale-forming minerals, as

most water does, use a well-maintained water

softener. Whether an exchangeable softener

cartridge or a regenerating system is chosen, a

regular exchange system is essential.

3.3 Installing a water meter between the softener and

the steamer will provide an accurate gauge of

water use, and will help determine when to

exchange cartridges or regenerate the softener.

Using a water softener will provide longer

generator life, higher steam capacity, and reduce

maintenance requirements.

3.4 If you notice a slowdown in steam production,

check the unit for scale build-up. Heavy scale

reduces the unit’s ability to boil water, and can

even cause heating elements in the steam

generator to overheat and burn out.

MINIMIZE SCALE PROBLEMS BY USING AND

MAINTAINING A SOFTENER, AND BY CLEANING

THE STEAMER REGULARLY.