Cables – UNICOM Electric GST-2402 User Manual

Page 33

Advertising
background image

Console Port to 9-Pin DTE Port on PC

9-Pin
Serial Port

CCITT Signal
PC’s 9-Pin

DTE Port

2 RXD

<---------RXD ------------

3 TxD

3 TXD

-----------TXD ---------->

2 RxD

5 SGND

-----------SGND ----------

5 SGND

Cables

The RJ-45 ports on the switch support automatic MDI/MDI-X operation, so

you can use standard straight-through or crossover twisted-pair cables to

connect to any other network device (PCs, servers, switches, routers, or

hubs). Please refer to the following table for cable specifications:

Cable Types and Specifications

Cable

Type

Max. Length

Connector

10BASE-T

Cat. 3, 4, 5

100-ohm UTP

100 m (328 ft)

RJ-45

100BASE-TX

Cat. 5 100-ohm

UTP

100 m (328 ft)

RJ-45

100BASE-FX

50/125 or 62.5/125

micron core

multimode fiber

(MM)

2 km (1.24 miles)

SC or ST

Cable specification table

100BASE-TX/10BASE-T Pin Assignments

With a 100BASE-TX/10BASE-T cable, pins 1 and 2 are used for transmitting