Operating instructions ‐ continued – United States Stove Company PELLET 5660(I) User Manual

Page 11

Advertising
background image

11 

OPERATING INSTRUCTIONS  continued 

 

the Auger feed rate will help keep the flames from extinguishing on the minimum heat level setting.  You can also 
use the AUGER TRIM button to lower heat output on the minimum heat level setting: 
 Depress  and  release  the  AUGER  TRIM  button  until  the  heat  level  1  and  5  setting  lights  appear  to  slightly 

increase the feed rate on the minimum heat level. 

 Depress  and  release  the  AUGER  TRIM  button  until  the  heat  level  1  and  4  setting  lights  appear  to  slightly 

reduce  the  pellet  feed  rate  on  the  minimum  heat  level  setting.    Use  this  setting  to  reduce  the  heat  level 
output on low.  

 Depress and release the AUGER TRIM button until only the heat level 1 setting light is on, this is the factory 

setting and works for most types of fuel. 

 

Open  Door:   

During  normal  operation  the  heater  will  automatically  shut  off  if  the  viewing  door  is  opened  for 

more than 30 seconds.  This action causes the heater to go into vacuum error mode.  To clear this error and restart 
the heater, close the door, depress the ON/OFF button and then follow directions for restarting heater.  

 

 
Refilling the Fuel Hopper:  

For maximum performance do not let the pellet fuel hopper drop below 1/4 full. 

 

Fuel  Hopper  Lid  Safety  Switch:   

When  the  Fuel  Hopper  Lid  is  opened  the  auger  will  stop  turning  to  prevent 

accidental injury. 

 

  

KEEP PELLET FUEL HOPPER LID CLOSED AT ALL TIMES EXCEPT WHEN REFILLING. DO NOT OVERFILL HOPPER.  

 
Safety Features and warning code: 

1.

Your heater is equipped with a temperature “high‐limit” switch, designed to shutdown the auger in case of 
an over temperature situation.  The high‐limit switch is a thermo snap disc type and must be manually reset 
in the event of an overheat shutdown.  Once the heater has cooled down, you can reactivate the high‐limit 
switch by depressing the manual reset button located on the high‐limit switch.  

2.

When the High‐Limit switch opens, which indicates an overheat failure, the HEAT LEVEL LED’s 3 & 4 will flash 
red. 

3.

Your  heater  is  equipped  with  a  vacuum  switch  that  automatically  shuts  down  the  auger  in  the  event  of  a 
exhaust fan malfunction. 

4.

When a Vacuum Error is sensed, the HEAT LEVEL LED’s 1 & 2 will flash red. Check to ensure the glass door is 
latched properly.  

5.

When the Low‐Limit switch opens, (fire went out) the HEAT LEVEL LED’s 4 & 5 will flash red. First check fuel 
supply, then check to ensure Auger is not jammed and finally that pellet hopper door is properly closed. 

6.

When the Pellets in the Burn Pot fail to ignite HEAT LEVEL LED’s 1 & 5 will flash red.  

 

 

NOTE: In the event that the high‐limit switch or vacuum switch activates, please contact your dealer to discuss 
the cause of this activation and to ensure that your heater continues to operate in a safe manner.  Either switch 
tripping can indicate a problem with the operation of your heater. 

 

 
 