Clearances to combustibles – United States Stove Company PELLET 5660(I) User Manual

Page 13

Advertising
background image

13 

USA 6”

CANADA 8”

USA 6”

CANADA 8”

CLEARANCES TO COMBUSTIBLES

 

INSTALL ALL VENTS AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER! 

 

When your Pellet Stove Room Heater is being installed on a combustible floor it is mandatory that a 1/2" 
(13mm)  thick  non‐combustible  hearth  pad  be  installed  under  the  heater.  The  non‐combustible  hearth 
pad must extend at least 6” beyond the fuel loading and ash removal openings and at least the depth of 
the heater plus 6 inches (152mm) out in front of the heater.  This applies to both freestanding heaters 
and insert heaters. 
 

 
 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 