Operating instructions ‐ continued, Figure 3 – United States Stove Company PELLET 5660(I) User Manual

Page 10

Advertising
background image

10 

OPERATING INSTRUCTIONS ‐ continued 

 

Control Board Functions:  

 
MODE  Button: 

The  MODE  button  allows  you  to  switch  operating  mode  on 

your Pellet Stove Room Heater.  Depress the MODE button to switch between 
Manual  and  T‐STAT  modes.    As  you  depress  the  MODE  button  the  indicator 
light above the desired mode will engage.  When you engage the Manual mode, 
you  will  be  able  to  manually  select  the  heat  settings.    If  you  have  installed  a 
remote  thermostat  for  your  Pellet  Stove  Room  Heater  and  wish  to  have  the 
heater  controlled  by  that  thermostat,  depress  the  MODE  button  to  engage  T‐
STAT  mode.    The  thermostat  will  control  the  heat  output  of  the  Heater 
alternating between  the lowest heat level and the  highest  heat  level that you 
have pre‐selected.

 

The T‐STAT mode provides the most even heat output, for better comfort, and 
to extend the life of the pellet fuel ignition system.  Additionally, the constant 
flame  serves  as  a  warning  for  people  and  pets  to  keep  away  from  the  heater 
while it is in operation. 

ON/OFF  Button:    The  ON/OFF  button  is  used  to  turn  the  heater  on  and  off. 
Whenever  there  is  power  to  the  heater,  the  LED  indicator  light  above  the 
ON/OFF  button  will  be  solid  red.    If  the  heater  is  cold  prior  to  start‐up,  press 
and  release  the  ON/OFF  button.  The  LED  light  above  the  ON/OFF  button  will 
alternately  flash  red  and  green  to  indicate  the  startup  cycle  has  started.  Fuel 
pellets will start to feed into the burn pot and the pellet fuel ignition system will 
be  activated.    Flames  in  the  burn  pot  will  normally  appear  between  4  ‐  8 

minutes, and once the flame has been established, the startup cycle will end, this takes between 8‐12 minutes.  At 
this  point  the  LED  indicator  light  above  the  ON/OFF  button  will  glow  solid  green.  The  user  will  now  be  able  to 
make heat level adjustments. 

HEAT  LEVEL  Button:  Depress the HEAT LEVEL button to advance the heat level by one level until you reach the 
maximum  setting;  from  the  maximum  level  you  will  decrease  one  level  each  time  you  depress  the  HEAT  LEVEL 
button.  The  circulation  fan  speed  will  also  increase  with  the  heat  level  setting.  Wait  until  the  startup  cycle  is 
complete and the ON/OFF LED is solid green to set Heat Level. (The HEAT LEVEL LEDs are also used as codes to 
indicate a malfunction, please refer to the 

Safety Features and warning codes

 section for more information.) 

FAN  Button:  Depressing  the  FAN  button  will  set  the  circulation  fan  speed  to  high,  overriding  the  automatic  fan 
speed  control.    The  onboard  logic  will  modulate  the  fan  speed  in  accordance  with  the  heat  level  setting.  It  is 
recommended that you allow the control to automatically set and adjust the speed of the fan to obtain optimum 
efficiency and minimal fan noise. 

AUGER  Button:  Whenever  Operating  the  Pellet  Stove  for  First  Time,  or  if  The  Stove  Runs  Out  Of  Pellets,  it  is 
Necessary to Prime the Auger with Pellet Fuel.  To do this, Press and Hold the AUGER Button for Approximately 3 
Seconds until the AUGER LED illuminates.  This Procedure will prime the Auger and then Automatically Initiate the 
Normal Ignition Cycle.  NOTICE: Do not use this procedure for normal startup.  To do so would cause excessive 
fuel build‐up in the burn pot.
 

AUGER  TRIM  Button:  This  Button  is  only  enabled  when  operating  at  Heat  Level  1.  Depress  the  AUGER  TRIM 
Button to change the Auger feed rate on the minimum heat level; to account for the quality of pellet fuel being 
used.  Increasing  

 

Figure 3  

Advertising
This manual is related to the following products: