MAINTENANCE ‐ continued 

 

Cleaning 

 

Heat Exchanger Tubes – Your Pellet Stove Room Heater is designed with a built in heat exchanger tube cleaner. 
This should be used every 2 or 3 days to remove ash build up on the heat exchanger tubes, which can reduce heat 
transfer.  The  handle,  for  the  heat  exchanger  tube  cleaner,  is  located  in  front  of  the  vent  tubes  on  front  side  of 
heater. Slide the rod front to back several times to clean the tubes then follow the instructions for ash removal. 

 

 

 
 
 
 
 
 
 
 

 
Fans – DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT 
 

Over  time  ash  or  dust  may  accumulate  on  the  blades  of  the  circulation  &  exhaust  fans.  The  fans  should  be 
inspected, periodically, and if any accumulation is present vacuumed clean as the ash or dust can impede the fans 
performance. It is also possible that creosote may accumulate in the exhaust fan, this must be brushed clean. 
 
The exhaust fan can be found behind the left side panel (facing the front of the heater), the circulation fan can be 
found behind the right side panel. To access the igniter, remove the air inlet tube and cover (2 screws) (Figure 27). 

 
Note: When cleaning take care not to damage the fan blades. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Figure 26

 

Figure 27

WARNING: DO NOT ATTEMPT TO OPERATE THE HEAT EXCHANGE TUBE 
CLEANER WHILE THE PELLET STOVE IS IN OPERATION OR COOLING 
DOWN; WAIT UNTIL PELLET STOVE HAS COOLED COMPLETELY BEFORE 
PERFORMING THIS PROCEDURE. 