Installation into a masonry fireplace – United States Stove Company PELLET 5660(I) User Manual

Page 28

Advertising
background image

28 

Installation into a Masonry Fireplace: 
 

 
 
 
 
 
 
 
 
 

1. Your  chimney  must  be  inspected  by  a  certified 

chimney  sweep  or  installer  to  determine  its 
structural condition. 

2. Measure amount of venting required to top chimney 

plus  14”  to  ensure  the  termination  is  adequate 
distance above the roofline. 

3. The  first  5’  of  exhaust  will  be  Simpson  Dura  Vent 

pellet stove flex vent; the remainder uses rigid pipe.  
For  each  joint  subtract  1‐1/2”  to  allow  for  the 
overlap.  You  may  need  an  adjustable  length  section 
to achieve the correct height. The air intake may be 
2” aluminum flex vent. 

4. Assemble the first rigid section of exhaust pipe to the 

flex  vent  pipe  insuring  that  the  “UP”  arrows  shown 
on the pipe labels are pointing up.  Connect sections 
and  twist  to  lock.  Repeat  the  process  for  the 
remainder  of  the  pipe  sections  and  lower  the 
assembly  down  the  chimney.    Lower  the  intake  and 
exhaust  pipes  below  their  normal  position  to 
connect the pipe to back of heater.  Tie a line to the 
top section of venting to pull it back up to the correct 
position. 

5. Connect  to  the  exhaust  of  the  stove  by  installing  a 

pipe  adapter  to  the  exhaust  fan  and  either  a  90º 
elbow or a clean out tee with cap.  The air intake can 
be attached to the heater with a hose clamp. 

6. Connect the heater to the coupling on the bottom of 

the  exhaust  flex  vent  and  twist  to  the  locked 
position.    Push  the  heater  into  the  fireplace  to  its 
final position. 

7. From the top of the chimney, pull the vent system up 

to the desired height. 

8. For the exhaust termination of the pellet vent use a 

tall  cone  flashing  and  a  storm  collar.  This  requires 
14”  of  pipe  above  the  top  of  the  masonry  chimney. 
Pull  the  pipe  up  through  the  flashing  to  the  desired 
height and mark where the storm collar will go. Slip 
the storm collar down over the pipe and fasten it to 
the  pipe  with  a  1/4”  stainless  steel  sheet  metal 
screw.  The  storm  collar  will  then  support  the  entire 
exhaust vent system. 

9. Install  the  air  intake  vent  through  the  chimney  cap 

by cutting a hole and install cap as shown or attach 
air  intake  vent  to  a  flashing  and  cap.  The  chimney 
top  must  be  properly  sealed  to  prevent  rain  and  or 
snow from entering the chimney. 

10. Install the cap and seal around the joint of the storm 

collar and any other joints that are visible. 

 

Perform these instructions in reverse if the removal of this appliance is ever needed for maintenance or 
repair.