TROUBLE SHOOTING 

 

See figure 26, page 31, for component locations

 
The heater will not light: 
 Check that the heater is plugged in and that the wall outlet has power. 
 Unplug the unit then check all electrical connections against the Wiring Diagram in this manual. 
 Check the fuse on the circuit board. 
 If a thermostat is used, ensure it is calling for heat. 
 If your heater still does not light contact your local dealer for service. 
 
The heater will not operate when hot. 
 Check that the fuel hopper has enough pellets. 
 Check that the combustion air inlet is not blocked. Insufficient air supply may cause the fire to burn 

cold and may cause fuel build up, in the pot, and smother the fire. 

 Check  that  the  exhaust  fan  is  operating,  if  the  fan  is  not  operating  properly  it  may  not  generate 

enough vacuum in the firebox.  

 Check the 200°F high limit switch. This switch is manually reset, check if it has tripped, if so let cool 

and reset switch. Check for cause of overheating, if switch trips again contact your local dealer for 
service 

 Check the vacuum switch by shorting out the vacuum switch then depress ON/OFF button to "OFF" 

and back to “ON”. If the unit starts to operate change the vacuum switch. 

 Check the exhaust temperature switch (located on the exhaust blower) by shorting out the exhaust 

temperature  switch  then  depress  ON/OFF  button  to  "OFF"  and  back  to  “ON”.  If  the  unit  starts  to 
operate change the exhaust temperature switch. 

 
Exhaust blower does not operate normally. 
 Check all wiring connections. 
 Apply 120 volts directly to the exhaust blower, if the blower does not run replace the blower. 
 
Circulation blower does not operate normally. 
 Check all wiring connections 
 Apply 120 volts directly to the circulation blower, if the blower does not run replace the blower. 

 

Igniter will not light fuel. 
 Check electrical connections (including fuse) to the igniter 
 Check  that  the  igniter  tube,  which  touches  the  burn  pot,  is  not  plugged  with  ash.  If  it  is  plugged 

remove the debris (be sure to wait until everything has cooled to room temperature) 

 Check to see that burn pot is installed correctly (see page 29)  
 If igniter still does not work, replace it. 
Note: The igniter should be glowing orange when in operation. 

 