Installation

2-21

Installing Standalone Units

Installation
Procedure

The standalone enclosure already contains a 6505

PLUS

, 6507

PLUS

, or 6525

PLUS

card.

To install the unit, follow these steps:

Rear View

Figure 2-2 shows the rear view of the standalone enclosure.

..

Figure 2-2. Rear View of Standalone Enclosure

Step

Action

Description/Result

1

Place the unit at its designated site
and plug the power cord into a
suitable primary power source.

The power cord is attached to the
back of the unit (Figure 2-2).

2

Switch on the power, located at the
rear of the unit.

The front panel lights turn on
as described in the “Power-Up
Verification” section on
page 2-74.

After a few minutes, the green
STATUS light comes on to indicate
the node is ready to process calls.
If this does not occur, call your
VanguardMS representative.

3

Configure the unit through the
Control Terminal Port (CTP)
menus.

To access the CTP, attach a
terminal to Port 6 with an EIA
232-D connector. Port 6’s default
settings are standard terminal port
values: 9600 baud, 8 data bits, 1
stop bit, no parity.

4

When the (*) prompt appears on
the terminal, type the following:

.

ctp <CR>

At the password prompt, press

<CR>

This is the default password value.

The Main menu appears. See the
Vanguard ONS Basics Protocols
Manual (T0106)
for configuration
information.

PORT 6

PORT 5

PORT 4

PORT 3

PORT 2

PORT 1