Installation

Installing Nodes in Modulus Enclosures

Guidelines for
Installing a TRIM
Card in a Modulus
8/18

Consider the following if you install a TRIM card in a Modulus 8/18 enclosure:

Note

Before you add a TRIM card to an existing node, be sure the enclosure has room
for it as described above. To make space, you may need to rearrange cards and
backplanes, which requires a node shutdown first.

• A processor card with attached TRIM card requires four slots — two slots for

the TRIM card and two for the processor card.

• You can attach a TRIM card only to the processor card in the

lowest-numbered slot of a backplane (this is the master processor
in a multi-processor node).

• There must be two empty slots beside the backplane next to the

lowest-numbered processor card.

• The TRIM card rear filler panel covers the back of the two slots taken by the

TRIM card. This rear panel, which has a cutout for the LAN port connectors,
covers the TRIM card backplane (Figure 2-8). Two standard Modulus 8/18
front filler panels cover the front of the TRIM card’s slots (Figure 2-9).

• When installing in a Modulus 18 enclosure, a metal screen must be installed

onto the Modulus 18 door to meet FCC requirements. See the “Preparing
Modulus Enclosures for RFI Suppression” section on page 2-49.

Advertising