6 serial communications, 1 rs-232 connection and port configuration, 2 serial command syntax – Vidikron Vision 12 User Manual

Page 65: Table 6-1 . serial commands, Serial communications, Rs-232 connection and port configuration, Serial command syntax, Pre l iminar y

Advertising
background image

Vidikron Vision Model 10/Model 12 Owner’s Operating Manual

55

PRE

L

IMINAR

Y

6.1
RS-232 Connection and
Port Configuration

To interface the Vision 10/12 with a home theater automation/control system or a PC
running terminal emulation software, connect it to your control system or PC as shown in
Figure 3-11.

Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop bit
and no flow control. Set the baud rate to 9600, to match that of the Vision 10/12 RS-232 port.

6.2
Serial Command Syntax

Table 6-1 lists the RS-232 command set. All commands are in ASCII format and must be in
UPPERCASE.

When you send a valid command, the Vision 10/12 executes it and acknowledges it with the
first three characters of the command followed by “OK;” for example,

RRAOK

. When you send

an invalid command, the Vision 10/12 ignores it and returns the first three characters of the
command followed by “NG;” for example,

RRXNG

.

6

Serial Communications

Table 6-1. Serial Commands

Command

Description

Reply

RRA00

Saves current settings to the CUSTOM 1 memory
(Note 1)

RRAOK

RRA01

Saves current settings to the ISF Day memory (Note 1)

RRAOK

RRA02

Saves current settings to the ISF Night memory
(Note 1)

RRAOK

RRB00

Recalls the Custom 1 memory settings

RRBOK

RRB01

Recalls the ISF Day memory settings

RRBOK

RRB02

Recalls the ISF Night settings

RRBOK

RRC00

Selects the S-VIDEO input

RRCOK

RRC01

Selects the COMPOSITE VIDEO input

RRCOK

RRC02

Selects the COMPONENT 1 input

RRCOK

RRC03

Selects the COMPONENT 2 input

RRCOK

RRC04

Selects the HDMI input

RRCOK

RRC05

Selects the RGB input

RRCOK

RRD00

Selects the ANAMORPHIC (16:9) aspect ratio

RRDOK

RRD01

Selects the STANDARD (4:3) aspect ratio

RRDOK

Notes:

1. All image quality settings must be made with the remote control. After the image adjustments are

complete, you can use these commands to store the settings in the selected memory.

2. The power on command (PON) will not provide an OK reply; it will instead reply with a random character.

For your automation system, simply ensure that you receive a character after the PON command. If you
do not get any reply after PON, send PON again.

Advertising
This manual is related to the following products: