Operating Instructions and Parts Manual

Safety Guidelines

This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.

Danger indicates an

imminently

hazardous

situation which, if not avoided, WILL result
in death or serious injury.

Warning indicates a

potentially

hazardous

situation which, if not avoided, COULD
result in death or serious injury.

Caution indicates a

potentially

hazardous

situation which, if not avoided, MAY
result in minor or moderate injury.

Notice

indicates

important

information, that if not followed, may
cause damage to equipment.

G eneral Safety Information

CALIFORNIA PROPOSITION 65

This product or its

power cord contains

chemicals known to the State of
California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.

GENERAL SAFETY

Do

not

use to

pump fl ammable or
explosive fl uids such as
gasoline, fuel oil, kerosene,
etc. Do not use in a fl ammable and/or
explosive atmosphere. Pump should
only be used to pump clear water.
Personal injury and/or property damage
could result.

All wiring must be

performed by a

qualifi ed electrician. Failure to follow
this warning could result in fatal
electrical shock.

If

the

basement has water or
moisture on the fl oor, do not
walk on wet area until all
power is turned off. If the shutoff box is in
the basement, call an electrician. Remove
pump and either repair or replace. Failure
to follow this warning could result in fatal
electrical shock.

Do

not

expose

battery to sparks or fl ames
as an explosion or fi re could
result.

Battery

acid

is

corrosive. Avoid spilling
on skin or clothing. Eye
protection must be worn
when handling the battery.

A ground fault

circuit interrupter is

required.

This pump must only

be used to pump

clear water. This pump is not designed
to handle effl uent, salt water, brine,
laundry discharge or any other
application which may contain caustic
chemicals and/or foreign materials.
Pump damage may occur if used in these
applications and will void warranty.

Back-up Pump Battery
Requirements

1. Use only a new fully charged 12

volt deep cycle battery. Electrolyte
level must be checked and
maintained in accordance with
manufacturer’s guidelines.

2. Battery sizes that will fi t into the

battery box are 24C, 24VCM, 27C,
27CM and 27F.

3. Battery recharge time will be

different at each installation. Under
normal conditions it will take two
to four days to bring a deep cycle
battery back to full charge after it
has been discharged. If electrical
power to the house is lost more
than once a week, consider keeping
a spare, fully-charged battery to
replace an exhausted battery for the
standby sump pump.

Installation

1. Install in a sump pit per the

minimum diameter required (WSS10:
11 inch, WSS20: 12 inch, WSS30: 15
inch in diameter). Construct sump
pit of tile, concrete, steel or plastic.
Position primary pump switch AWAY
from any inlets so that incoming
water does not contact the switch
face. See Figure 1(a) - 1(c).

2.

The unit should be located and
rest on a solid, level foundation.
Do not place pump directly on clay,
earth, gravel or sandy surface. These
surfaces contain small stones, gravel,
sand, etc. that may clog or damage
the pump and cause pump failure.

Flood risk. If fl exible

discharge hose is

used, make sure pump is secured in
sump pit to prevent movement. Failure
to secure pump could allow pump
movement and switch interference and
prevent pump from starting or stopping.

3. Using PVC cement and primer,

connect 1-1/4 inch or 1-1/2 inch (only
1-1/2 inch for WSS30) rigid pipe to
the system's discharge fi tting.

Support

pump

and piping when

assembling and after installation.
Failure to do so could cause piping to
break, pump to fail, etc. which could
result in property damage and/or
personal injury.

4. Place battery in box. Attach red

cable from battery box control panel
to positive battery terminal. Attach
black cable to the negative terminal.
Place cover on battery box.

www.waynepumps.com

Check valve

24 inch min.

Inlet
pipe

Grounded
Outlet

Grounded
Outlet

11 inch
Diameter
min.

Figure 1 (a)

Discharge pipe

Cap Switch

ON @ 8 inches

OFF @ approx. 3 inches

WSS10