Parameter reference table, Control supplement & service guide – Weil-McLain ULTRA 230 User Manual
Page 51

51
Part number 550-100-029/0810
GAS
-
FIRED
WATER
BOILER
SERIES
1 & 2
— Control supplement & Service guide
Parameter reference table
(continued)
Para.
Name
Range
Boiler display
Description
Display position:
1st
2nd
3rd
4th
7
T4
maximum
(see page 44)
60 to 78
Initial reading:
s
MAXIMUM
s
MAXIMUM
TEMPERATURE
P
.
0
7
After 2 to 3 seconds:
"LANK
"LANK
Setting
8
T4
frost
protection
-22 to 50
Initial reading:
s
CONSTANTLY
P
.
0
8
After 2 to 3 seconds:
"LANK
Setting
9
T4
correction
(see page 44)
- 8 to 10
Initial reading:
s
CORRECT
P
.
0
9
After 2 to 3 seconds:
"LANK
"LANK
Setting
10
T
blocking
(see page 44)
32
OFF
34 – 140
Initial reading:
s
SHUTS
P
.
1
0
After 2 to 3 seconds:
"LANK
Setting
11
Booster
time
(see page 46)
0 to 30
Initial reading:
s
PARAMETER
s
P
.
1
1
After 2 to 3 seconds:
"LANK
"LANK
Setting
12
T
parallel
shift
0 to 144
Initial reading:
s
AMOUNT
s
DEFAULT
P
.
1
2
After 2 to 3 seconds:
"LANK
Setting
13
Maximum
fan speed
CH
(see page 47)
13 to 52
S
Initial reading:
s
#(
s
SETTING
s
P
.
1
3
14 to 58
S
After 2 to 3 seconds:
"LANK
Setting
15
Maximum
fan speed
DHW
(see page 47)
13 to 52
S
Initial reading:
s
HEATING
s
)NCREASING
s
P
.
1
5
14 to 58
S
After 2 to 3 seconds:
"LANK
"LANK
Setting
See Figure 25, page 42 for procedure to access Parameter settings.