C

LEANING THE

S

PRAY

G

UN

C

OMPONENTS

1. Perform Pressure Relief Procedure, page 5.

2. Remove spray gun from the

paint hose using adjustable
wrenches.

3. Remove filter from spray gun

(refer to Unclogging the
Spray Gun Filter,
page 8).

4. Remove spray tip from

spray guard assembly.

5. Clean spray tip and filter with a soft-bristled brush and the

appropriate cleaning solution. Be sure to remove and clean
the washer and saddle seat located in the rear of the spray
tip assembly.

6. Pour a few drops of household oil inside the gun housing

(see area indicated below by arrow).

7. Reassemble spray gun:

• install gun filter tapered-end

first, and,

• install spray tip, saddle

seat and washer, and
replace spray guard
assembly.

8. Thread the paint hose back onto the spray gun. Tighten

with a wrench.

IMPORTANT!

If you cleaned your pump using mineral spirits, it is
recommended that you flush the pump again using warm,
soapy water to prepare it for storage. Repeat Flushing
the Pump instructions.

Housing

Filter

Washer

Saddle

seat

Housing

Filter

Customer Service: 800-328-8251

10

© 2003 Wagner Spray Tech - All rights reserved.

English

C

LEANUP

(

CONTINUED

)

C

LEANING THE

I

NLET

V

ALVE

1. Remove the inlet filter from

the bottom of the hopper.
You may need to use a
screwdriver to pry the filter
loose.

2. Insert the inlet valve tool into

the inlet fitting. Twist
counter-clockwise and
remove from its housing.

3. Inspect the three inlet fitting

O-rings on the inlet fitting.
Clean or replace, and
lubricate with household oil.

4. Retrieve the inlet valve and

the inlet valve O-ring from
the inlet fitting housing.
Clean or replace and
lubricate the O-ring with a
light household oil.

5. Set the inlet valve O-ring

back into the housing, and
set the inlet valve on top of it.

6. Replace inlet fitting into the

housing. Tighten with the
inlet valve tool and ratchet.

R

EPLACING THE

O

UTLET

V

ALVE

1. Unscrew the outlet valve from the outlet valve housing using

an adjustable wrench.

2. Inspect the inside of the

outlet valve housing.
Remove any
accumulated paint.

3. Replace with a new

outlet valve. Tighten
into outlet valve
housing with an
adjustable wrench.

Replacement of the outlet valve may be necessary if
your spray performance remains poor after having
performed all the steps contained in the Spraying
Troubleshooting section of this manual. Replacement
valves are available by calling customer service.

DO NOT remove the O-rings
on the inlet fitting to clean
them. Remove ONLY if you
plan to replace them.

Inlet fitting
O-ring

Inlet fitting
O-ring

Inlet fitting
O-ring

Inlet
fitting

Inlet
valve

Inlet
valve
O-ring

You willl need to attach the inlet valve tool to a ratchet
wrench extension in order to remove it.

Cleaning or servicing the inlet valve may be required if
the unit has priming problems. This may be caused by
improper cleaning and/or storage. Replacement kits
may be ordered by calling customer service.