GOLD CGa Gas-Fired Water Boiler — Boiler Manual

Ratings

Install CGa boilers for residential radiant panel systems, converted gravity heating systems or other low water

temperature applications per instructions in this manual to avoid damage due to condensation.

CGa boilers are CSA design certified for installation on combustible flooring.

CGa boilers are ASME rated for 50 psig working pressure.

Table 7 Ignition system model suffixes

13b

Boiler

model

number

Input

(Btuh)

DOE

Heating

capacity

(Btuh)

0–2,000 feet

altitude

2,000–4,500 feet

altitude

Net

I=B=R

ratings

(Btuh)

Boiler
water

content
(gallons)

DOE

Seasonal efficiency

(% A.F.U.E)

Chimney

and

breeching

size

Input

(Btuh)

Output

(Btuh)

Input

(Btuh)

Output

(Btuh)

SPDN

SPDL

PIDN

(Note 1)

(Note 2)

(Note 3)

CGa-25

52,000

44,000 52,000 44,000

46,800 39,000 38,000

1.5

81.5

83.3

84.0

4"I.D. x 20’

CGa-3

70,000

59,000 70,000 59,000 63,000 53,000 51,000

1.5

81.6

83.7

84.0

4"I.D. x 20’

CGa-4

105,000

88,000 105,000 88,000

94,500 79,000

77,000

2.1

81.7

83.7

84.0

5"I.D. x 20’

CGa-5

140,000

117,000 140,000 117,000 126,000 105,000 102,000

2.7

81.8

83.7

83.5

6"I.D. x 20’

CGa-6

175,000

146,000 175,000 146,000 157,500 131,000 127,000

3.3

81.9

83.6

83.2

6"I.D. x 20’

CGa-7

210,000

175,000 210,000 175,000 189,000 157,000 152,000

3.8

82.0

83.6

83.0

7"I.D. x 20’

CGa-8

245,000

204,000 245,000 204,000 220,500 183,000 177,000

4.4

82.1

83.6

82.7

7"I.D. x 20’

Notes

1. See Table 7 for available pilot systems. The suffix shown in the table is added to the boiler model number. (Not

available for millivolt systems.)

2. Based on standard test procedures prescribed by the United States Department of Energy.
3. Net I=B=R ratings are based on net installed radiation of sufficient quantity for the requirements of the building

and nothing need be added for normal piping and pickup. Ratings are based on a piping and pickup allowance of
1.15. An additional allowance should be made for unusual piping and pickup loads.