Pro Wall Hood Specifications

8

Discharge Specifications

LOW-PROFILE WALL HOODS

The illustrations provide dimensions for discharge options

for low-profile wall hoods. These dimensions are critical

for proper installation. Dimension A in the illustrations will

vary with the width of the hood. Refer to the chart below.

Low-Profile Wall Hoods

WIDTH OF HOOD

A

30"

(762)

14

3

/

4

"

(375)

36"

(914)

17

3

/

4

"

(451)

42"

(1067)

*

20

3

/

4

"

(527)

48"

(1219)

*

23

3

/

4

"

(603)

*500 CFM blower not available for these hood widths.

A

TO

CENTER OF

TRANSITION

1

1

/

2

"

(38)

2"

(51)

TO CENTER

OF TRANSITION

Horizontal discharge.

9"

(229)

5

5

/

8

"

(143)

TO CENTER

OF TRANSITION

A

TO

CENTER OF

TRANSITION

Vertical discharge with accessory transition.

1

1

/

2

"

(38)

2

5

/

8

"

(60)

TO CENTER

OF TRANSITION

A

TO

CENTER OF

TRANSITION

Vertical discharge.

LOW-PROFILE WALL HOODS DISCHARGE OPTIONS

DISCHARGE

CUT-OUT

3

1/4

"

(83)

14"

(356)

Cut-out without transition.