XLT 020111

Carefully remove your WhisperKOOL unit from the box. Do not destroy your packing material, as it

provides the only safe means of transporting the unit. Units weigh 65–100 pounds and are cumbersome

for one person to carry. We recommend that you get someone else to help you during the installation

process.

Testing Unit

Place the WhisperKOOL system on a tabletop to

prepare it for installation and testing. Locate the

by-pass plug and insert it into the thermostat

plug, located on the front of the WhisperKOOL

System. Next, plug the system into a live electrical

outlet and turn the unit on. The system should

begin cooling. The system may take up to 10 to 15

minutes before running cool. Once the operation

has been tested, turn the unit off, unplug the unit

from the electrical outlet, remove the by-pass

plug, and install thermostat.

Note: If the system does not seem to be

running cool after 15 minutes, please refer to

the Troubleshooting Guide on page 19.

Before installation, use the by-pass

test plug to test the unit.

Attach precut foam tape to the unit’s flange.

Foam Tape

Adhesive Covering

Flange

Test Plug

Applying Insulation Tape

Locate the four precut pieces of black foam tape

included with your system. There should be two larger

pieces and two smaller pieces. Start with the large

pieces. Peel back the white-paper adhesive covering,

and attach the large pieces to the sides of the unit

flange. Then follow with the two smaller pieces on the

top and bottom. This foam creates a tight seal between

the unit’s flange and the wall (see illustration).

Note: Failure to install foam strips may void the

warranty.

Liquid Measuring Thermostat System

To assure a consistent temperature, place bottle probe

approximately 3 feet away from the air output and not

in the flow of the air.

.