USING THE WHISPERKOOL SYSTEM

®

FRONT

REAR

OFF

POWER

Location of control switches

Switches

Power Switch

XLT units, built after June 2007, come equipped with a

3-position ON/OFF power switch. The upper position activates

power from the cellar side outlet located on the side of unit. The

bottom position activates power from the rear position outlet.

The center position is OFF and is simply used when the owner

does not need to utilize the equipment.

NOTE; (It will take five minutes before the unit begins to

operate once the switch is placed in the “On” position. This

is due to the designed safety delay in the PDT thermostat.)

Condensate Evaporator Switch

The Condensate Evaporator is a heating element that automatically evaporates excess condensate that

accumulates in the cooling system as a by-product of refrigeration. Only the WhisperKOOL units are

equipped with sophisticated heating elements that automatically sense the presence of water and work

continually until the water is gone. Setting the Condensate Evaporator to the “On” setting causes the

heating element and the right exhaust fan to stay on continuously to prevent excess condensation from

building up in the unit.

Drain Line

All units come with a drain line for additional

removal of excessive condensate. This is a back up

system to the Condensate Evaporator. It is

mandatory to install the drain line attachment.

During operation, the cooling unit will strip excess

water from the air in order to maintain the proper

level of humidity within the cellar. The Condensate

Evaporator will heat and dissipate the excess

moisture through the rear of the unit. However in

extreme humidity, additional condensate will be

created. Conversely the high humidity air has less

capacity to absorb additional moisture through the

exhaust of the unit. Thus the drain line will prevent

overflow and leaking by allowing for discharge of

the additional condensate. WhisperKOOL carries a

condensate pump kit, which allows the excess

condensate to be pumped up to 20 ft. away from

the unit. See page 29 for details.

Failure to install the drain line voids warranty.

To prevent mold from growing, allow the

drainline to hang above the water line.