NORMAL OPERATION

WhisperKOOL

systems are designed to maintain both temperature and humidity. Once the system is

installed and the temperature set, it will run continuously until the wine cellar is at your set wine

temperature. This may be as long as three weeks, depending on the size of the room, the quality

(R-value) of insulation, the original temperature of the wine, and the number of bottles residing in the

cellar. Once the cellar has achieved the set temperature, the WhisperKOOL unit will cycle to maintain

±1°F of your set temperature.

Note: Defrost Cycle will turn off the unit for 5 minutes every 90 minutes to allow any accumulated

frost to dissolve.

The WhisperKOOL

system will run more often than a refrigerator or air conditioner, due to its

gentle cooling and humidity maintenance.

People often make the mistake of comparing the performance of refrigerators with the performance

and cycling of wine storage equipment. Wine cellar cooling systems are highly specialized and designed

for one purpose only–long term storage of wine.

Maintenance

The following maintenance should be performed on your WhisperKOOL

unit at least once every six

months to promote longevity and optimal performance.

Vacuum the WhisperKOOL

unit to clean the evaporator and condenser coils to prevent air blockage. The

condenser coils reside behind the grill on the back of the WhisperKOOL

unit. Don’t try to open the unit

yourself. Just vacuum the surface of the grill and remove any lint or dust that has accumulated.

Humidity Control

There are no separate switches in order to maintain humidity. The cooling unit is designed to maintain

relative humidity at 50-70%.

The WhisperKOOL units do not create humidity. If you live in a dry area of the country you many need

to create humidity in the wine cellar. This can be done by introducing a non-heat humidifier, or installing

a small fountain within the cellar.

MAINTENANCE SCHEDULE

Monthly

1. Check for unusual noise or vibration

2. Check the drainline to see if it is above the waterline if draining into a vessel.

Quarterly

1. Clean front and rear intake grilles.

Annually

1. Use a vacuum with brush attachment to clean grilles.
2. Inspect for corrosion.
3. Check wiring connections and integrity of cords.

4. Pour a 50/50 bleach solution into the drainline every spring.

It is the user’s responsibility to remove any accumulated dust, lint, or other debris from the front and rear intake

grilles. This will restrict the airflow and may affect the unit’s ability to function properly. Periodically cleaning the

unit’s vents will help assure maximum cooling efficiency. The drain tube must also be checked and kept clean and

free of debris and mold to maintain proper performance.